Wattmaster WM-WCC3-TGD-01B User Manual

Browse online or download User Manual for Equipment Wattmaster WM-WCC3-TGD-01B. WattMaster WM-WCC3-TGD-01B User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 846
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
W
CC III
Operator’s Guide
WCC III
VAV/Zone Controller
Technical Guide
WCC III
VAV/Zone Controller
Actuator Package
Technical Guide
Master Catalog
8500 N.W. River Park Drive
Parkville, MO 64152
Toll Free Phone: 866-918-1100
PH: (816) 505-1100
FX: (816) 505-1101
Visit our website:
www.wcc-controls.com
WM-WCC3-BIND-IDX-01B
For Master Binder: WCC3MASTER-ALL-01B
Page view 0
1 2 3 4 5 6 ... 845 846

Summary of Contents

Page 1 - Master Catalog

WCC III Operator’s Guide WCC III VAV/Zone Controller Technical Guide WCC III VAV/Zone Controller Actuator Package Technical Guid

Page 2

Table of ContentsSECTION 3: WCC3.EXE SCREEN DESCRIPTIONS, continued Analog Global Math Function Mode Screen ... 3-140Analog Global Look Up Table Mode

Page 3 - Training Guide

2. INITIATING THE SYSTEMWCC III Technical Guide2-32Introduction to Processes Every program, process or command running on a Linux system is a process.

Page 4

2. INITIATING THE SYSTEMWCC III Technical Guide2-33Webmin Administration - Limited Version

Page 5 - Part Numbers

2. INITIATING THE SYSTEMWCC III Technical Guide2-34WCC III - MCD Linux Base System InstallationWCCIII – MCD Linux Base System InstallInstall the Softw

Page 6

2. INITIATING THE SYSTEMWCC III Technical Guide2-35Step 7: When prompted, you should highlight and select Yes when you’re asked, “Write the changes t

Page 7

2. INITIATING THE SYSTEMWCC III Technical Guide2-36How to Setup a Windows-Based Local User’s Computer with a Direct Connection (Ethernet Crossover Cab

Page 8 - WEBMIN ADMINISTRATION

2. INITIATING THE SYSTEMWCC III Technical Guide2-37You must change a couple of network settings, but they are not diffi cult if you take a couple of mi

Page 9

2. INITIATING THE SYSTEMWCC III Technical Guide2-38Step by Step InstructionsTo get the “Network Connections” icon you must be able to navigate to the

Page 10

2. INITIATING THE SYSTEMWCC III Technical Guide2-39At the Internet Protocol (TCP/IP) Properties dialog screen you must select the “Use the Following I

Page 11 - WCCUTILITY.EXE SCREENS

2. INITIATING THE SYSTEMWCC III Technical Guide2-40Adding a Compact Flash Hard Drive Card to the WCC III - MCD ComputerUnder Windows XP on the WCC III

Page 12

2. INITIATING THE SYSTEMWCC III Technical Guide2-41Step 4d: Next, right mouse click on the TRANSCEND drive under the “Volume label” (or other manufac

Page 13

Table of ContentsWCC III VAV BOX III TREND LOGGING ... 4-15FORCE MODES OR OVERRIDES ... 4-16SCUSCR.EXE SCREENS ...

Page 14 - WCC III INSTALLATION GUIDE

2. INITIATING THE SYSTEMWCC III Technical Guide2-42Formatting DisksThe fi rst step in copying disks is to format the disk which will serve as the “Targ

Page 15 - INSTALLATION GUIDE

3. WCC3.EXE Screen 3. WCC3.EXE Screen DescriptionsDescriptionsWCC III

Page 16

TABLE OF CONTENTSSECTION 3: WCC3.EXE SCREEN DESCRIPTIONSHow to Start or Run the WCC3.exe Program...3-1WCC III Main Menu Tool Bar ...

Page 17 - OE430-01 INSTALLATION

TABLE OF CONTENTSPID Programs ... 3-113Simple PID Programs Screen...

Page 19 - GLOBAL BRIDGE MANUAL

WCC III Technical Guide3-1WCC3.EXE SCREEN DESCRIPTIONSSECTION 3: WCC3.EXE SCREEN DESCRIPTIONS

Page 20

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-2The Remote Access Dialog Box will allow you to enter multiple WCC III – MCD IP addresses based u

Page 21 - I. Introduction

WCC III Technical Guide3-3WCC3.EXE SCREEN DESCRIPTIONSWCC III Main Menu Tool BarWhen you open the WCC III program and each of its available screens, y

Page 22 - INTRODUCTION

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-4Action Menu The <Action> menu has many functions. These functions’ availability are tied

Page 23

WCC III Technical Guide3-5WCC3.EXE SCREEN DESCRIPTIONSCopy Screen From Previous ScreenWhile at the Home position at the screen you wish to copy the da

Page 24

SECTION 5: WCCUTILITY.EXE SCREENS, continuedBACKUP SATELLITES ... 5-23BACKUP GLOBALS ...

Page 25 - System Features

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-6Plot When data is available to graph, for example, in the Trend Logs screens, you can select <

Page 26

WCC III Technical Guide3-7WCC3.EXE SCREEN DESCRIPTIONSWhen you click inside the Search For fi eld, the Edit Logic Address Dialog Window will appear:You

Page 27 - Software Updates

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-8Special Purpose KeysThe special purpose keys are a very powerful and necessary part of the WCC I

Page 28 - SATELLITE TYPES

WCC III Technical Guide3-9WCC3.EXE SCREEN DESCRIPTIONS <Ctrl><K>: Clear Communication ErrorsThe WCC III system keeps track of the tra

Page 29

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-10The Main Menu Screen allows you to view the available screens within the WCC III system. To get

Page 30

WCC III Technical Guide3-11WCC3.EXE SCREEN DESCRIPTIONS Active alarms in classes:If an alarm is active within the system, the alarm type number will a

Page 31 - Satellite Types - SAT 3D

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-12An analog input is a signal sent to the satellite controller that can be represented by a numbe

Page 32 - SAT 3D (OE455) - Figure I-6

WCC III Technical Guide3-13WCC3.EXE SCREEN DESCRIPTIONSCurrent ValueThe current value of the analog input is automatically displayed here.Alarm Limits

Page 33 - Satellite Types - SAT 3F

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-14Satellite # _______Specifi es the number of the satellite which you are currently editing. If yo

Page 34 - SAT 3F (OE456) - Figure I-7

WCC III Technical Guide3-15WCC3.EXE SCREEN DESCRIPTIONSSensor TypeThis is a choice fi eld for Analog types only. A list of available choices will be di

Page 35

SECTION 10: RS-485 COMMUNICATIONS ANDTROUBLESHOOTINGWCC III – MCD AND SAT III TYPECONTROLLERS “RS-485 NETWORK LOOP” COMMUNICATIONS ...

Page 36 - Board - (OE431-01) (SS5006)

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-16------ALARMS------Controlled by:Specifi es the binary value that selects the ON or OFF alarm lim

Page 37 - & OE430-02) (SS5008)

WCC III Technical Guide3-17WCC3.EXE SCREEN DESCRIPTIONS ------ BINARY SETPOINTS ------____Above:________Below:____These inputs are used to convert th

Page 38

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-18Satellite # _______Specifi es the number of the satellite which you are currently editing. If yo

Page 39

WCC III Technical Guide3-19WCC3.EXE SCREEN DESCRIPTIONSAnalog Input Pulse ScreenPattern for Values Associated With This Input:Specifi es where you woul

Page 40

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-20There are two fi elds on this screen that determine which set of limits are active—the status of

Page 41

WCC III Technical Guide3-21WCC3.EXE SCREEN DESCRIPTIONSAnalog Input Thermistor Screen ANALOG INPUT THERMISTOR SCREENAnalog Input Screen’s WCC III Lo

Page 42 - Introduction to Fiber Optics

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-22Analog Input Thermistor ScreenSensor TypeThis is a choice fi eld for Analog types only. A list o

Page 43

WCC III Technical Guide3-23WCC3.EXE SCREEN DESCRIPTIONSAnalog Input Thermistor ScreenLimits Low HighOn _____ _____ °. FOff _____ _____ °

Page 44 - TUC-2R Controller - ( OE320)

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-24Analog Input Screen

Page 45

WCC III Technical Guide3-25WCC3.EXE SCREEN DESCRIPTIONSVOUTGND+VAT I1TO 81TO 8NONELOADRESISTOR2 WIRE THERMISTOR TYPE - Thermistor Scaling FactorFLUSHM

Page 46

SECTION 11: WCC III ALARMING, continuedANALOG GLOBAL AND BINARY GLOBAL ALARMS... 11-5ALARM

Page 47

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-26VOUTGND+VAT I1 TO 81 TO 8NONELOADRESISTOR3 WIRE VOLTAGE TYPE - 0 to 1 Volt Scaling FactorFLUSHM

Page 48 - VAVZ II Controller

WCC III Technical Guide3-27WCC3.EXE SCREEN DESCRIPTIONSAnalog Input Screen

Page 49 - Part Numbers - Boards

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-28Analog Input Screen

Page 50 - Part Numbers - Sensors

WCC III Technical Guide3-29WCC3.EXE SCREEN DESCRIPTIONSAnalog Input Screen

Page 51

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-30notAnalog Input Screen

Page 52

WCC III Technical Guide3-31WCC3.EXE SCREEN DESCRIPTIONSAnalog Input Screen

Page 53 - 1. General Instructions

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-32VOUTGND+VAT I1TO 81TO 8NOLOADRESISTORInput Jumper must be set to THERMThere are berg jumpers th

Page 54 - INSTRUCTIONS

WCC III Technical Guide3-33WCC3.EXE SCREEN DESCRIPTIONSAnalog Input ScreenFOR 0-10 VOLT INPUTS

Page 55

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-34Analog Input Screen

Page 56 - WCC III Software

WCC III Technical Guide3-35WCC3.EXE SCREEN DESCRIPTIONSAnalog Input Resistor Screen ANALOG INPUT RESISTOR SCREENAnalog Input Screen’s WCC III Logica

Page 57 - Analog Inputs

TUC-2R AND FOUR RELAY EXPANSIONBOARD ... 12-67TUC-2R THREE RELAY EXPANSION BOARDAND DAMPER ACTUATOR

Page 58 - Binary Inputs

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-36Sensor TypeThis is a choice fi eld for Analog types only. A list of available choices will be di

Page 59

WCC III Technical Guide3-37WCC3.EXE SCREEN DESCRIPTIONSThere are two fi elds on this screen that determine which set of limits are active—the status of

Page 60 - Analog Outputs

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-38Analog Input Resistor+ Screen ANALOG INPUT RESISTOR+ SCREENAnalog Input Screen’s WCC III Logi

Page 61 - Binary Outputs

WCC III Technical Guide3-39WCC3.EXE SCREEN DESCRIPTIONSSensor TypeThis is a choice fi eld for Analog types only. A list of available choices will be di

Page 62 - Point Addresses

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-40Alternate Limits Selected By:Specifi es the point that initiates the Alternate mode. When this a

Page 63 - Data Registers

WCC III Technical Guide3-41WCC3.EXE SCREEN DESCRIPTIONSAnalog Input RawCount Screen ANALOG INPUT RAWCOUNT SCREENAnalog Input Screen’s WCC III Logica

Page 64

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-42Sensor TypeThis is a choice fi eld for Analog types only. A list of available choices will be di

Page 65 - Alarm Call-Out

WCC III Technical Guide3-43WCC3.EXE SCREEN DESCRIPTIONSThere are two fi elds on this screen that determine which set of limits are active—the status of

Page 66

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-44Analog Input Thermistor+ ScreenSatellite # 1 ANALOG INPUT # 2 Description: Room

Page 67 - 2. Initiating the System

WCC III Technical Guide3-45WCC3.EXE SCREEN DESCRIPTIONSSensor TypeThis is a choice fi eld for Analog types only. A list of available choices will be di

Page 68 - SECTION 2: INITIATING THE

Initiating the System ...13B-11WCCIII-MCD2 System Files ...13B-11Various I/O Connections ...

Page 69

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-46Alternate Limits Selected By:Specifi es the point that initiates the Alternate mode. When this a

Page 70 - Full WCC3 Installation

WCC III Technical Guide3-47WCC3.EXE SCREEN DESCRIPTIONSThermistor+ ScreenThe Thermistor+ Screen is to be used if you are using a thermistor type senso

Page 71

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-48Analog Input Thermistor+ Screen Temperature / Resistance / Voltage Chartfor the BAPI™ (Alerton™

Page 72 - Limited WCC3 Installation

WCC III Technical Guide3-49WCC3.EXE SCREEN DESCRIPTIONSAnalog Input Thermistor+ ScreenTemp(ºF)Temp(ºC)Resistance(Ohms)Voltage @ Input (VDC)21 -6.11 13

Page 73

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-50Analog Input Thermistor+ Screen Thermistor Sensor Testing InstructionsUse the resistance colum

Page 74

WCC III Technical Guide3-51WCC3.EXE SCREEN DESCRIPTIONS CONTROL OUTPUT SCREENSThe Control Output Screens are used to “tell” the satellite controller

Page 75

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-52Control OutSpecifi es the summary type to be displayed. Because this is a “choice” fi eld, the li

Page 76

WCC III Technical Guide3-53WCC3.EXE SCREEN DESCRIPTIONSSTATUSA message is displayed here to help you monitor the status of the equipment being control

Page 77

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-54Satellite #:_____Specifi es the number of the satellite you are currently editing. If you would

Page 78

WCC III Technical Guide3-55WCC3.EXE SCREEN DESCRIPTIONSYou make your selection by pressing the <space bar> until the desired point type appears

Page 79 - Setting Passcodes

SAT III ANALOG OUTPUT WIRING ... 14-17SAT III BINARY INPUT WIRING... 14-22INPUT/OUTPUT TERMINOLOGY ...

Page 80

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-56Satellite #: _____Specifi es the number of the satellite you are currently editing. If you woul

Page 81

WCC III Technical Guide3-57WCC3.EXE SCREEN DESCRIPTIONSYou may make your selection by pressing the <space bar> once for each choice until the de

Page 82

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-58The multiplier is automatically selected based on the data pattern for the analog input associa

Page 83

WCC III Technical Guide3-59WCC3.EXE SCREEN DESCRIPTIONSSatellite #: ____Specifi es the number of the satellite you are currently editing. If you would

Page 84

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-60Description: _____________A short message is entered here which will be displayed on Summary an

Page 85

WCC III Technical Guide3-61WCC3.EXE SCREEN DESCRIPTIONSControl Output Time Clock Screen

Page 86

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-62Control Output Time Clock Screen

Page 87

WCC III Technical Guide3-63WCC3.EXE SCREEN DESCRIPTIONSAn analog output is a proportional DC voltage supplied by the SAT III with a maximum range of 0

Page 88

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-64MODEAn “alt” message may be displayed in this column to inform you that analog output is in its

Page 89

WCC III Technical Guide3-65WCC3.EXE SCREEN DESCRIPTIONSSatellite # _____Specifi es the number of the satellite you are currently editing. If you would

Page 90

WCC3 V-OUT RELAY BOARDCONNECTIONS ... 16-4WCC3 V-OUT RELAY BOARD INSTALLATION AND MOUNTING ...

Page 91

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-66To make your selection, press the <space bar> once for each choice until the desired fi lt

Page 92

WCC III Technical Guide3-67WCC3.EXE SCREEN DESCRIPTIONSAnalog Output Screen

Page 93

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-68SAT TREND LOGGINGThe WCC III system SAT III Controller has four trend modes described below. A

Page 94

WCC III Technical Guide3-69WCC3.EXE SCREEN DESCRIPTIONSSAT Trend LogSpecifi es the summary type to be displayed. Because this is a “choice” fi eld, the

Page 95

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-70 Satellite # 1 TREND LOGGING # 1 of Type: CHANGE OF STATE Records time & dat

Page 96 - Custom Commands Modules

WCC III Technical Guide3-71WCC3.EXE SCREEN DESCRIPTIONSSatellite #: _____Specifi es the number of the satellite you are currently editing. If you would

Page 97

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-72Current run time: _____ secondsThis is the current accumulated run time. You may select the uni

Page 98

WCC III Technical Guide3-73WCC3.EXE SCREEN DESCRIPTIONSSatellite #: ____Specifi es the number of the satellite you are currently editing. If you would

Page 99

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-74Record value of: ______once every _____ minutesSpecifi es the [analog] point address for which

Page 100 - 2. INITIATING THE SYSTEM

WCC III Technical Guide3-75WCC3.EXE SCREEN DESCRIPTIONSSatellite #: ____Specifi es the number of the satellite you are currently editing. If you would

Page 101

Table of ContentsTYPICAL WCC III SYSTEM COMMUNICATIONS WIRING – NOT THE RECOMMENDED AND PREFERRED WAY ... 1

Page 102

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-76Logic SwitchSpecifi es the summary type to be displayed. Because this is a “choice” fi eld, a lis

Page 103

WCC III Technical Guide3-77WCC3.EXE SCREEN DESCRIPTIONSThe Logic Switch Screen looks the same as the Logic Switch Summary Screen except for the locat

Page 104 - WCC III Technical Guide

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-78Confi gON Board OFF BoardON Board is the corresponding dipswitch on the cover of the SAT III, i

Page 105

WCC III Technical Guide3-79WCC3.EXE SCREEN DESCRIPTIONS87SATADDRESS2148A 3WIRE ROOM SENSOR WILL NOTREQUIRE ALOAD RESISTOR WHEN SETFOR A1 VOLT INPUT.Wa

Page 106

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-80SAT III CONTROLLER87SAT ADDRESS2148A 3 WIRE ROOM SENSOR WILLNOTREQUIRE ALOAD RESISTOR WHEN SETF

Page 107

WCC III Technical Guide3-81WCC3.EXE SCREEN DESCRIPTIONS Binary Output Satellite # __2 Sat. #2 Time Date 08:49 1/23

Page 108

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-82Mode when using the Analog ModeThe “alt” message will appear here when the Analog Mode Alternat

Page 109

WCC III Technical Guide3-83WCC3.EXE SCREEN DESCRIPTIONSWCC III Binary Output Board / V-Out Board SequenceThere are two versions of the WCC III V-Out B

Page 110

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-84The Dipswitch on the WCC3 V-Out Relay Board sets the various modes of operation and dead band i

Page 111 - Descriptions

WCC III Technical Guide3-85WCC3.EXE SCREEN DESCRIPTIONS BINARY OUTPUT SCREEN Satellite # 1 BINARY OUTPUT # 3 Description: S1-B

Page 112 - TABLE OF CONTENTS

Form: WCC3MASTER-ALL-01B Copyright October 2013 WattMaster Controls, Inc. WattMaster Controls, Inc. assumes no responsibility for errors or omissi

Page 114

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-86Minimum Off Time: ____ MinutesMinimum On Time: ____ MinutesSpecifi es the minimum ON and OFF t

Page 115

WCC III Technical Guide3-87WCC3.EXE SCREEN DESCRIPTIONS Alarm Summary Time Date Address Class Pending Description Alarm Message(s)

Page 116 - Running the WCC3 Program

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-88Sat #:Twenty satellites will appear on each Satellite Summary Screen. If your system has more t

Page 117 - WCC III Main Menu Tool Bar

WCC III Technical Guide3-89WCC3.EXE SCREEN DESCRIPTIONSSpecifi c points may be soft-started within the satellite by using the Shed/Restore Programs. (

Page 118

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-90The data pattern tables for the satellite controllers need to be rebuilt whenever any of the fo

Page 119

WCC III Technical Guide3-91WCC3.EXE SCREEN DESCRIPTIONS OVERRIDE SCHEDULES Starting

Page 120 - Set Color

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-92 --------Start-------- ---------End---------TIME MONTH DAY TIME MONTH DAYEn

Page 121

WCC III Technical Guide3-93WCC3.EXE SCREEN DESCRIPTIONSThe week schedule will obey the entries listed on the HOL line when a holiday occurs. In this e

Page 122 - Special Purpose Keys

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-94The WCC3 System Parameters Screen is used to enable, disable, and setup E-mailing of Alarms for

Page 123

WCC III Technical Guide3-95WCC3.EXE SCREEN DESCRIPTIONSThe User Name can be up to 30 characters (control codes, ALT codes, and the double quote charac

Page 124 - Main Menu Screen

I. IntroductionI. IntroductionWCC III

Page 125

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-96E-Mail SMTP Server:(SMTP) Simple Mail Transfer Protocol is an Internet standard for electronic

Page 126 - Analog Input Summary Screen

WCC III Technical Guide3-97WCC3.EXE SCREEN DESCRIPTIONSRepeatThe “Repeat” function is time in minutes to send out a repeated E-mail after the fi rst e-

Page 127

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-98OperatorSpecifi es the password that identifi es an operator. A character, symbol, number or a s

Page 128 - Analog Input General Screen

WCC III Technical Guide3-99WCC3.EXE SCREEN DESCRIPTIONS On/Off Messages 1. On 11. Fan ON 21. Chlr. ON 2. Off

Page 129

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-100 Alarm Messages 1. Low Temp 21. -21- 41. -41- 2. High Temp Alarm 22. -22

Page 130 - ------ALARMS

WCC III Technical Guide3-101WCC3.EXE SCREEN DESCRIPTIONSSECURE THE SYSTEMThis position on the Main Menu Screen is used for signing off after you are fi

Page 131

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-102 ENERGY CONSUMPTION SCREENE N E R G Y C O N S U M P T I O N S U M M A R Y 1 08:2

Page 132 - Analog Input Pulse Screen

WCC III Technical Guide3-103WCC3.EXE SCREEN DESCRIPTIONSThe units selected will appear for the consumption since last reset and also for the monthly c

Page 133

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-104Energy Consumption Screen

Page 134

WCC III Technical Guide3-105WCC3.EXE SCREEN DESCRIPTIONS87SAT ADDRESS2148A 3 WIRE ROOM SENSOR WILLNOTREQUIRE ALOAD RESISTOR WHEN SETFOR A1 VOLT INPUT.

Page 135

INTRODUCTIONWCC III SYSTEM FEATURES ...I-1WCC III - MCD ...I-2Diagram

Page 136

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-106 Custom Slide 1. ScrTest 1 21. 41. 2. ScrTest 2 22. Test 22 42. 3. ScrTe

Page 137

WCC III Technical Guide3-107WCC3.EXE SCREEN DESCRIPTIONS<Ctrl-U> Toggle UpdatingThe values of the WCC III points on the Custom Screen are “dynam

Page 138 - Analog Input Screen

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-108Custom ScreensAt the top of the WCC3.exe screen there is a pull down menu under “File” selecti

Page 139

WCC III Technical Guide3-109WCC3.EXE SCREEN DESCRIPTIONS Bitmap Slide 1. Bmptest 1 21. 41. 2. Bmptest 2 22. 42. 3.

Page 140

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-110Use the following procedure to cause the WCC III to read the fi le from the Bitmap Screen Progr

Page 141

WCC III Technical Guide3-111WCC3.EXE SCREEN DESCRIPTIONSBitmap ScreensThese end-user created bitmap screens can also be kept in the SlideFiles subdire

Page 142

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-112 Network Information Internal Static IP Address: 192.168.200.200 External Stati

Page 143

WCC III Technical Guide3-113WCC3.EXE SCREEN DESCRIPTIONSPID Programs PID PROGRAMPID program stands for Proportional-Integral-Derivative control. The

Page 144

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-114PID Programs Screen - SIMPLE SIMPLE PID PROGRAMS SCREENProgram Number:This specifi es which PI

Page 145

WCC III Technical Guide3-115WCC3.EXE SCREEN DESCRIPTIONSPID Programs ScreenPID Mode:This tells the PID program to run one of the three supported formu

Page 146 - 0-5V INPUT

I. INTRODUCTIONWCC III Technical GuideI-1System FeaturesINTRODUCTION: WCC III SYSTEM FEATURES__________________________________________The question

Page 147 - FOR 0-10 VOLT INPUTS

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-116MODIFIED PID PROGRAMS SCREENModifi ed PID ModeProportional Gain:This defi nes the Proportional

Page 148

WCC III Technical Guide3-117WCC3.EXE SCREEN DESCRIPTIONSDigital PID Programs Screen DIGITAL PID PROGRAMS SCREENDigital PID ModeProportional Gain:This

Page 149 - Analog Input Resistor Screen

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-118 TUNING PID PROGRAMS SCREENThe purpose of PID tuning is to fi nd out the intrinsic characteris

Page 150

WCC III Technical Guide3-119WCC3.EXE SCREEN DESCRIPTIONSPID Tuning ScreenSource Stable Hysteresis:This tells the PID program how much range the source

Page 151

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-120 WEEK SCHEDULE SUMMARY SCREEN Week Schedule Summary W 1 Time Date 08:23

Page 152 - Analog Input Resistor+ Screen

WCC III Technical Guide3-121WCC3.EXE SCREEN DESCRIPTIONSWEEK SCHEDULE _____Specifi es the number of the week schedule which you are currently editing.

Page 153

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-122 OPTIMAL START SCREEN Optimal Start # 7 ON Time Date 08:26

Page 154

WCC III Technical Guide3-123WCC3.EXE SCREEN DESCRIPTIONSOUTDOOR SENSORINDOOR SENSOR: Specifi es the location of the indoor and outdoor temperature sens

Page 155 - Analog Input RawCount Screen

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-124Adaptive ModeThe “required major adjustment” message will appear when the Optimal Start Screen

Page 156

WCC III Technical Guide3-125WCC3.EXE SCREEN DESCRIPTIONSANALOG GLOBALSThe WCC III system has 256 analog globals. The term “ analog” means a numerical

Page 157

I. INTRODUCTIONWCC III Technical GuideI-2System FeaturesWCC III - MCD The acronym WCC III - MCD stands for the WattMaster Controls Center III (Version

Page 158

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-126ANALOGSpecifi es the summary type to be displayed. Because this is a “choice” fi eld, the list o

Page 159

WCC III Technical Guide3-127WCC3.EXE SCREEN DESCRIPTIONSAnalog Global #:____Specifi es the global number and its type. Because this is a “choice” fi eld

Page 160

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-128The term local set means that communication is lost between the MCD and the satellite controll

Page 161

WCC III Technical Guide3-129WCC3.EXE SCREEN DESCRIPTIONSMode 1: Averaged ListValue to be averagedYou may input up to 8 analog values to be averaged.

Page 162

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-130Mode 2: Sorted ListValues to be sortedYou may input up to 8 analog values to be sorted. The v

Page 163

WCC III Technical Guide3-131WCC3.EXE SCREEN DESCRIPTIONSRangeThe system has the capability of generating an alarm if the value of this global analog i

Page 164

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-132Sampling From:The value of the global analog will be the accumulated total of this input over

Page 165 - Control Output Screens

WCC III Technical Guide3-133WCC3.EXE SCREEN DESCRIPTIONSThe sampling rate programmed amount of time can be in minutes or hours. Because this is a “cho

Page 166 - Control Output Summary Screen

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-134ANALOG GLOBAL - INTEGRAL MODE AVERAGE MODEThe integral mode can be used to obtain an averag

Page 167

WCC III Technical Guide3-135WCC3.EXE SCREEN DESCRIPTIONSSampling From:The value of the global analog will be the average of this input over the specifi

Page 168 - EA DRIVER SCREEN

I. INTRODUCTIONWCC III Technical GuideI-3System FeaturesDiagram of WCC III SystemThe heart of the WCC III system consists of an Internet Appliance re

Page 169

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-136The sampling rate programmed amount of time can be in minutes or hours. Because this is a “cho

Page 170 - DUAL LIMIT SCREEN

WCC III Technical Guide3-137WCC3.EXE SCREEN DESCRIPTIONS ANALOG GLOBAL - INTEGRAL MODESLIDING WINDOWAssume that we want to know the average kW dema

Page 171

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-138Mode 3: Integral Sampling From:The value of the global analog will be the average of this inp

Page 172

WCC III Technical Guide3-139WCC3.EXE SCREEN DESCRIPTIONSThe sampling rate window can be programmed for number of minutes, hours, days, or samples. Bec

Page 173 - TIME CLOCK SCREEN

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-140Mode 4: Math FunctionGlobal Value = ((2A5-2A6)/(2A5-GA3))*100The math formula to be calcula

Page 174

WCC III Technical Guide3-141WCC3.EXE SCREEN DESCRIPTIONS Relational FunctionsOperator CommentEqual to = = The combined expression is true if the value

Page 175

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-142This graph can be reconstructed within the WCC III system with the use of a look up table. For

Page 176

WCC III Technical Guide3-143WCC3.EXE SCREEN DESCRIPTIONSAnalog Global #:____Specifi es the global number and its type. Because this is a “choice” fi eld

Page 177 - Analog Output Summary Screen

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-144Data Pattern: _____Specifi es the number of signifi cant digits for analog global values display

Page 178

WCC III Technical Guide3-145WCC3.EXE SCREEN DESCRIPTIONSEach look up table has a graph associated with it which can be displayed on the screen. To vie

Page 179 - Analog Output Screen

I. INTRODUCTIONWCC III Technical GuideI-4WCC III OPERATOR CONTROL CONSOLE COMPONENTSThe building operator control console software ( WCC3.EXE, and o

Page 180

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-146Analog Global External Mode Screen ANALOG GLOBALEXTERNAL MODE SCREENAnalog Global Screen’s

Page 181

WCC III Technical Guide3-147WCC3.EXE SCREEN DESCRIPTIONSAnalog Actuator/Valve ControlUseful Analog Actuator/Valve Control InformationManually or solen

Page 182 - WCC III System Logging

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-148Analog Global Dual Valve ModeDual Valve Mode Dual Valve is used when two valves are used to co

Page 183 - SAT Trend Log Summary Screen

WCC III Technical Guide3-149WCC3.EXE SCREEN DESCRIPTIONSAnalog Global Dual Valve ModeMode 7: Dual ValveThe Global Analog Mode 7 Dual Valve Screen wa

Page 184

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-150Analog Global Dual Valve ModeValve 1 size:One Valve/Pump fl ow size ratio may be a different si

Page 185 - SAT Run Time Trend Log Screen

WCC III Technical Guide3-151WCC3.EXE SCREEN DESCRIPTIONSDuring Valve 2 modulation, If the control input drops below _____ % for more than stage ti

Page 186

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-152Analog Global Proportional Mode ScreenMode 8: ProportionThe Global Analog Mode 8 Proportion

Page 187

WCC III Technical Guide3-153WCC3.EXE SCREEN DESCRIPTIONSAnalog Global Proportional Mode ScreenRangeThe system has the capability of generating an alar

Page 188

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-154Analog Global Dual Ramp Mode ScreenMode 9: Dual RampThe Global Analog Mode 9 Dual Ramp Screen

Page 189

WCC III Technical Guide3-155WCC3.EXE SCREEN DESCRIPTIONSAnalog Global Dual Ramp Mode ScreenTime: There are two time values that should be set here—tim

Page 190 - Logic Switch Summary Screen

I. INTRODUCTIONWCC III Technical GuideI-5 WGCC3.EXE (SS5029) WGCC3.exe is a user access program. It allows for remote access via the Internet so that

Page 191 - Logic Switch Screen

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-156Mode 10: Multi-ProportionThe Global Analog Mode 10 Multi-Proportion Screen was created to pro

Page 192

WCC III Technical Guide3-157WCC3.EXE SCREEN DESCRIPTIONSRangeThe system has the capability of generating an alarm if the value of this global analog i

Page 193

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-158Mode 11: Pulse StartThe Global Analog Mode 11 Pulse Start Screen was created for opening and

Page 194 - SAT III CONTROLLER

WCC III Technical Guide3-159WCC3.EXE SCREEN DESCRIPTIONSAs the source value drops below _______,sets this global to ______.Otherwise, this global valu

Page 195 - Binary Output Summary Screen

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-160The WCC III system has 512 binary globals. The term “binary” simply means a value which is rep

Page 196

WCC III Technical Guide3-161WCC3.EXE SCREEN DESCRIPTIONSTime / DateThe present time and date will automatically appear at these locations.DescriptionT

Page 197 - V-Out Board Sequence

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-162 BINARY GLOBAL SCREEN BINARY Global #: 1 Name is GB1Description: Global Binary

Page 198

WCC III Technical Guide3-163WCC3.EXE SCREEN DESCRIPTIONSMode: 1 CombinatorialSpecifi es the mode used to generate the ON or OFF value of the binary gl

Page 199 - Binary Output Screen

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-164This second part of the sentence reads as “...when (ANY or ALL) of the following conditions ar

Page 200

WCC III Technical Guide3-165WCC3.EXE SCREEN DESCRIPTIONSMode: 2 CompareSpecifi es the mode used to generate the ON or OFF value of the binary global.

Page 201 - Alarm Summary Screen

I. INTRODUCTIONWCC III Technical GuideI-6 SATELLITE TYPES The satellite controllers are fi eld mounted and then fi eld programmed. The satellite control

Page 202 - Satellite Summary Screen

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-166Math Operators (>, = =, !=)The math operators are in a choice fi eld and therefore the list

Page 203

WCC III Technical Guide3-167WCC3.EXE SCREEN DESCRIPTIONSBinary Global External Mode Screen BINARY GLOBAL SCREENEXTERNAL MODEBinary Global Screen’s W

Page 204 - Rebuild Satellite Tables

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-168In Local Set this global defaults to _____.Specifi es the state (or value) of the binary global

Page 205 - Override Screen

WCC III Technical Guide3-169WCC3.EXE SCREEN DESCRIPTIONS BINARY GLOBAL SCREENALARM MODE BINARY Global #: 2 Name is GB5Description: Linux G

Page 206 - Holiday Schedule Screen

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-170Binary Global Alarm Mode Screen[NONE][Alarm NotAcknowledged]When these choices are selected, t

Page 207

WCC III Technical Guide3-171WCC3.EXE SCREEN DESCRIPTIONSMode: 5 Alarm-by-ClassSpecifi es the mode used to generate the ON or OFF value of the binary g

Page 208 - System Parameters Screen

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-172Binary Global Alarm-By-Class Mode ScreenIn Local Set this global defaults to _____.Specifi es t

Page 209

WCC III Technical Guide3-173WCC3.EXE SCREEN DESCRIPTIONS BINARY GLOBAL SCREENONE SHOT MODEBinary Global Screen’s WCC III Logical Address is GBXXX, wh

Page 210

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-174In Local Set this global defaults to _____.Specifi es the state (or value) of the binary global

Page 211

WCC III Technical Guide3-175WCC3.EXE SCREEN DESCRIPTIONSBinary Global Clock Mode Screen BINARY GLOBAL SCREENCLOCK MODEBinary Global Screen’s WCC III

Page 212 - Operator Codes Screen

I. INTRODUCTIONWCC III Technical GuideI-7• 1 HSS communications port that can connect and power up as many as 5 HSS expansion type boards.• 16 addit

Page 213

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-176When 5L3 is initially turned ON, this binary global will turn on. After 120 seconds this binar

Page 214 - Alarm Messages Screen

WCC III Technical Guide3-177WCC3.EXE SCREEN DESCRIPTIONSBinary Global Delay Mode Screen BINARY GLOBAL SCREENDELAY MODEBinary Global Screen’s WCC III

Page 215 - Secure the System

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-178Value is delayed_______seconds for________ .This is a two part statement. The fi rst part is a

Page 216 - Energy Consumption Screen

WCC III Technical Guide3-179WCC3.EXE SCREEN DESCRIPTIONSMode: 9 PWMSpecifi es the mode used to generate the ON or OFF value of the binary global. Beca

Page 217

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-180PWM Mode The PWM mode monitor analog input and convert it to binary output with pulse width mo

Page 218

WCC III Technical Guide3-181WCC3.EXE SCREEN DESCRIPTIONSMode: 10 Lead-Lag Specifi es the mode used to generate the ON or OFF value of the binary globa

Page 219 - CONTROLLER

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-182Current source status:This fi eld will display the current active state of the value that was p

Page 220 - Custom Screens

WCC III Technical Guide3-183WCC3.EXE SCREEN DESCRIPTIONSIn Local Set this global defaults to _____.Specifi es the state (or value) of the binary global

Page 221

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-184 SHED/RESTORE SCREENShed/Restore Program # 1Shed/Restore based on input: 3A1 and sch

Page 222

WCC III Technical Guide3-185WCC3.EXE SCREEN DESCRIPTIONSNOTE: To cause equipment to be turned off when the binary globals are turned off, use the bin

Page 223 - Bitmap Screens

www.wcc-controls.comwww.wcc-controls.comWCC IIITraining Guide

Page 224

I. INTRODUCTIONWCC III Technical GuideI-8 SAT 3C ( OE454) - Figure I-5 (SS5004)The new SAT 3C controller is an advanced product replacement for the o

Page 225

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-186 DUTY CYCLE SCREENDuty Cycling Program #: 1 Program is: 15 segments of: 1 minutes each

Page 226 - Network Information Screen

WCC III Technical Guide3-187WCC3.EXE SCREEN DESCRIPTIONSDuty Cycle ScreenNOTE: To cause equipment to be turned off when the binary globals are turned

Page 227 - PID PROGRAM

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-188Proportional #:Specifi es the number of the program you are currently editing. The WCC III has

Page 228 - SIMPLE PID PROGRAMS SCREEN

WCC III Technical Guide3-189WCC3.EXE SCREEN DESCRIPTIONSDesignate Setpoint to be Affected (*)An asterisk (*) is placed under the setpoint that is to b

Page 229 - PID Programs Screen

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-190This graph is accessed from the Proportional Reset Screen. To access the graph, select <Act

Page 230 - Modified PID Programs Screen

WCC III Technical Guide3-191WCC3.EXE SCREEN DESCRIPTIONSTo access this screen, select <Tenant Override> from the Main Menu. The user must have l

Page 231 - DIGITAL PID PROGRAMS SCREEN

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-192Caution: DO NOT enter the same output contact on two or more separate Tenant Utility Lists. Us

Page 232 - PID Tuning Screen

WCC III Technical Guide3-193WCC3.EXE SCREEN DESCRIPTIONS The General Message Screen is used to provide important information to all users of the

Page 233

WCC3.EXE SCREEN DESCRIPTIONSWCC III Technical Guide3-194

Page 234 - Week Schedule Summary Screen

4. SCUSCR.EXE Screens4. SCUSCR.EXE ScreensWCC III

Page 235 - Week Schedule Screen

I. INTRODUCTIONWCC III Technical GuideI-9Satellite Types - SAT 3D SAT 3D ( OE455) - Figure I-6 (SS5005)The new SAT 3D controller is an advanced prod

Page 236 - Optimal Start Screen

TABLE OF CONTENTSSECTION 4: SCUSCR.EXE SCREENSHow to Start or Run the SCUSCR.exe Program... 4-1Co

Page 237

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-1SECTION 4: SCUSCR.EXE SCREENS__________________________________________How to Start or Run the SCUSCR.

Page 238

WCC III Technical Guide4-24. SCUSCR.EXE SCREENSThe Remote Access Dialog Box will allow you to enter multiple WCC III – MCD IP addresses based upon “Jo

Page 239 - WCC III Logical Addressing

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-3Overview of ControllersController OverviewWattMaster Controls, Inc. produces a line of application-spec

Page 240 - Analog Global Summary Screen

WCC III Technical Guide4-44. SCUSCR.EXE SCREENSVAV OverviewVariable Air volume (VAV) is a technique for controlling the capacity of a heating, ventila

Page 241 - Analog Global Screen

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-5SCUSCR.EXE Screens IndexWCC VAV BOX III (WattMaster Software SS5010)Sequence of Operation 4-6Figure 4-1

Page 242

WCC III Technical Guide4-64. SCUSCR.EXE SCREENSWCC VAV BOX III Sequence of Operation (WattMaster Software Number SS5010)InitializationOn initial power

Page 243

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-7WCC III VAV BOX III SchedulingProportional Heating SignalIf the VAV box has hot water reheat using a pr

Page 244

WCC III Technical Guide4-84. SCUSCR.EXE SCREENSModes of OperationThere are 7 possible modes of operation for the HVAC Unit and the VAVBOX TUC-2R contr

Page 245 - ACCUMULATION MODE

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-9Occupied ModeIf the VAVBOX TUC-2R controller is used on a non-fan-powered terminal unit that has rehea

Page 246 - ACCUMULATION MODE SCREEN

I. INTRODUCTIONWCC III Technical GuideI-10SAT 3D (OE455) - Figure I-6The SAT 3D Controller has 8 status lights. The functions of these lights or LED

Page 247

WCC III Technical Guide4-104. SCUSCR.EXE SCREENSWhen the VAVBOX TUC-2R controller is in the Occupied Supply Air Heating mode, the damper will be held

Page 248 - AVERAGE MODE

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-11Series Flow Fan TerminalsIf the VAV/Zone Controller has been confi gured as a Series Fan Powered termin

Page 249 - AVERAGE MODE SCREEN

WCC III Technical Guide4-124. SCUSCR.EXE SCREENSIn all cases, before the series box fan can be activated, the air damper is driven fully closed and he

Page 250

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-13Box Fan Relay & Reheat Relay Staging Unoccupied ModeRelays Stage On AtSeries FanParallel FanHeat S

Page 251 - SLIDING WINDOW

WCC III Technical Guide4-144. SCUSCR.EXE SCREENSDamper ControlThe damper position is calculated by the mode and demand from the space sensor. Included

Page 252 - SLIDING WINDOW MODE SCREEN

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-15WCC III VAV BOX III Trend LoggingAlarm Detection and ReportingThe VAVBOX TUC-2R controller continuousl

Page 253

WCC III Technical Guide4-164. SCUSCR.EXE SCREENSForce Modes or OverridesThe VAVBOX TUC-2R controller damper can be forced to one of several positions.

Page 254 - MATH FUNCTION SCREEN

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-17SCUSCR.EXE SCREENSThe SCUSCR.exe program is used to access stand-alone controllers that have been prep

Page 255

WCC III Technical Guide4-184. SCUSCR.EXE SCREENSEach Sat3d uses up the address space of the equivalent of 4 regular SAT III controllers. See Table 4-4

Page 256 - LOOK UP TABLE MODE

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-19Location The Location fi eld is a user programmable fi eld name that is used to identify the location of

Page 257 - LOOK UP TABLE SCREEN

I. INTRODUCTIONWCC III Technical GuideI-11Satellite Types - SAT 3F SAT 3F ( OE456) - Figure I-7 (SS5016)The new SAT 3F controller is an advanced pro

Page 258

WCC III Technical Guide4-204. SCUSCR.EXE SCREENSSupply Air Mode:There are three types of Supply Air Modes: Supply Air Cooling Mode, Supply Air Heating

Page 259

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-21Damper PositionThis is a percentage of “OPEN” for the actuator and this corresponds to how much the ai

Page 260 - EXTERNAL MODE SCREEN

WCC III Technical Guide4-224. SCUSCR.EXE SCREENSOccupied Cooling Setpoint is the temperature setpoint that you wish to control the Zone’s space temper

Page 261 - Information

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-23 [ Damper / Airfl ow Settings ]____________________________{ % = PR Dep CFM = PR Indep }Damper / Ai

Page 262 - Analog Global Dual Valve Mode

WCC III Technical Guide4-244. SCUSCR.EXE SCREENSBox Size Constant for Airfl ow @ 1”WCIf this is a pressure independent box, this option allows you to c

Page 263

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-25VAV BOX CONTROLLERSatellite: _ 4 Unit: 1 Location: Version: 3.04[ GLOBAL BINARIES ]Unit operates in Oc

Page 264

WCC III Technical Guide4-264. SCUSCR.EXE SCREENSVAV BOX CONTROLLERSatellite: _ 4 Unit: 1 Location: Version: 3.04[ GLOBAL BINARIES ]Unit operates in Oc

Page 265

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-27VAV BOX CONTROLLERSatellite: _ 4 Unit: 1 Location: Version: 3.04[ MODE OF OPERATION ]Enter the proper

Page 266

WCC III Technical Guide4-284. SCUSCR.EXE SCREENSVAVBOX II for WCC III Software Screens (WattMaster Software #SS5001)Single Duct - Cooling Only Sequenc

Page 267

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-29EMS OffsetOn a command from the WCC III – MCD central processor, typically during peak load demand per

Page 268

I. INTRODUCTIONWCC III Technical GuideI-12Satellite Types - SAT 3FSAT 3F (OE456) - Figure I-7The SAT 3F Controller has 8 status lights. The functions

Page 269

WCC III Technical Guide4-304. SCUSCR.EXE SCREENSSingle Duct Cooling-Only ScreensThis is the main summary screen for the WCC3 VAV BOX II software for t

Page 270

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-31Current Cooling SetpointThis is the current cooling setpoint that the VAVBOX II software is controllin

Page 271

WCC III Technical Guide4-324. SCUSCR.EXE SCREENSOccupied Cooling Setpoint This is the temperature setpoint that you wish to control the Zone’s space t

Page 272

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-33Minimum Damper Position This is the minimum position that the actuator will close to. This depends on

Page 273

WCC III Technical Guide4-344. SCUSCR.EXE SCREENSFigure 4-8: Single Duct Cooling Only - Pressure Dependent Globals ScreenSingle Duct Globals and Mode

Page 274 - Binary Global Summary Screen

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-35Single Duct Globals and Mode of Operation ScreensForce Damper to Maximum Setpoint when GB(X)The VAVBOX

Page 275

WCC III Technical Guide4-364. SCUSCR.EXE SCREENSFigure 4-9: Single Duct Cooling Only - Pressure Dependent Mode of Operation ScreenSINGLE DUCT COOLING

Page 276 - Binary Global Screen

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-37Satellite: Unit:The satellite fi eld is used to input a valid SAT 3d address number. The unit

Page 277 - COMBINATORIAL MODE

WCC III Technical Guide4-384. SCUSCR.EXE SCREENSSingle Duct Cooling Only Pressure Independent Status ScreenSpace TemperatureThis is the current temper

Page 278

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-39Single Duct Cooling Only Pressure Independent Setpoint ScreenOccupied Cooling Setpoint This is the tem

Page 279 - COMPARE MODE

I. INTRODUCTIONWCC III Technical GuideI-13Satellite Types - SAT 3P SAT 3P ( OE455-P) - Figure I-8 (SS5013)The SAT 3P Controller is only used for up

Page 280

WCC III Technical Guide4-404. SCUSCR.EXE SCREENSSingle Duct Cooling Only Pressure Independent Setpoint ScreenAirfl ow @ 1” WG Box sizeIf this is a pres

Page 281 - EXTERNAL MODE

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-41VAVBOX II Globals ScreenThe VAVBOX II Globals Screen is used to set up the occupied/unoccupied conditi

Page 282

WCC III Technical Guide4-424. SCUSCR.EXE SCREENSSingle Duct Cooling Only Pressure Independent Globals ScreenForce Damper to Maximum Setpoint when GB(X

Page 283 - ALARM MODE

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-43Figure 4-13: Single Duct Cooling Only - Pressure Independent Setup ScreenSingle Duct Cooling Only Pre

Page 284

WCC III Technical Guide4-444. SCUSCR.EXE SCREENSFigure 4-14: Parallel Fan Powered - Pressure Dependent Status ScreenParallel Fan Powered Pressure Dep

Page 285 - ALARM-BY-CLASS MODE

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-45Parallel Fan Powered Pressure Dependent Status ScreenSpace TemperatureThis is the current temperature

Page 286

WCC III Technical Guide4-464. SCUSCR.EXE SCREENSFigure 4-15: Parallel Fan Powered - Pressure Dependent Setpoint ScreenParallel Fan Powered Pressure D

Page 287 - ONE SHOT MODE

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-47Parallel Fan Powered Pressure Dependent Setpoint ScreenStages of Box HeatingThis confi gures the 2nd an

Page 288

WCC III Technical Guide4-484. SCUSCR.EXE SCREENSParallel Fan Powered Pressure Dependent Globals ScreenVAV BOX II Globals ScreenThe VAV BOX II Globals

Page 289 - CLOCK MODE

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-49Parallel Fan Powered Pressure Dependent Globals ScreenForce Damper to Maximum Setpoint when GB(X)The V

Page 290

I. INTRODUCTIONWCC III Technical GuideI-14Accessory Boards - Binary Input with Time DelayOPTIONAL WCC III ACCESSORY BOARD TYPES WCC III Binary Input w

Page 291 - DELAY MODE

WCC III Technical Guide4-504. SCUSCR.EXE SCREENSFigure 4-17: Parallel Fan Powered - Pressure Dependent Mode of Operation ScreenParallel Fan Powered P

Page 292

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-51Parallel Fan Powered Pressure Independent Status ScreenFigure 4-18: Parallel Fan Powered - Pressure I

Page 293 - PWM MODE

WCC III Technical Guide4-524. SCUSCR.EXE SCREENSSpace TemperatureThis is the current temperature of the zoned area that the WCC3 VAVBOX II is controll

Page 294

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-53Parallel Fan Powered Pressure Independent Setpoint ScreenFigure 4-19: Parallel Fan Powered - Pressure

Page 295 - LEAD LAG MODE

WCC III Technical Guide4-544. SCUSCR.EXE SCREENSStages of Box HeatingThis confi gures the 2nd and 3rd relay on the relay expansion board. We allow for

Page 296

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-55Parallel Fan Powered Pressure Independent Globals ScreenFigure 4-20: Parallel Fan Powered - Pressure

Page 297

WCC III Technical Guide4-564. SCUSCR.EXE SCREENSParallel Fan Powered Pressure Independent Globals ScreenForce Damper to Maximum Setpoint when GB(X)The

Page 298 - Shed/Restore Screen

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-57Figure 4-21: Parallel Fan Powered - Pressure Independent Mode of Operation ScreenParallel Fan Powered

Page 299

WCC III Technical Guide4-584. SCUSCR.EXE SCREENSSeries Fan Powered Pressure Dependent Status & Setpoint ScreensFigure 4-22: Series Fan Powered -

Page 300 - Duty Cycle Screen

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-59Series Fan Powered Pressure Dependent Globals & Setup ScreensFigure 4-24: Series Fan Powered - Pr

Page 301

I. INTRODUCTIONWCC III Technical GuideI-15Accessory Boards - Vout Relay WCC III V-Out Relay Board - ( OE430-01 & OE430-02) (SS5008)The WCC III Vo

Page 302 - Proportional Reset Screen

WCC III Technical Guide4-604. SCUSCR.EXE SCREENSSeries Fan Powered Pressure Independent Status & Setpoint ScreensFigure 4-26: Series Fan Powered

Page 303

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-61Series Fan Powered Pressure Independent Globals & Setup ScreensFigure 4-28: Series Fan Powered -

Page 304 - Proportional Reset Graph

WCC III Technical Guide4-624. SCUSCR.EXE SCREENSSingle Duct Changeover Pressure Dependent Status & Setpoint ScreensFigure 4-30: Single Duct Chang

Page 305 - Tenant Override Utility List

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-63Single Duct Changeover Pressure Dependent Globals & Setup ScreensFigure 4-32: Single Duct Changeo

Page 306

WCC III Technical Guide4-644. SCUSCR.EXE SCREENSSingle Duct Changeover Pressure Independent Status & Setpoint ScreensFigure 4-34: Single Duct Cha

Page 307 - General Message Screen

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-65Single Duct Changeover Pressure Independent Globals & Setup ScreensFigure 4-36: Single Duct Chang

Page 308

WCC III Technical Guide4-664. SCUSCR.EXE SCREENSSingle Duct Reheat Pressure Dependent Status & Setpoint ScreensFigure 4-38: Single Duct Reheat -

Page 309 - 4. SCUSCR.EXE Screens

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-67Single Duct Reheat Pressure Dependent Globals & Setup ScreensFigure 4-40: Single Duct Reheat - Pr

Page 310 - SCUSCR.EXE SCREENS

WCC III Technical Guide4-684. SCUSCR.EXE SCREENSSingle Duct Reheat Pressure Independent Status & Setpoint ScreensFigure 4-42: Single Duct Reheat

Page 311

4. SCUSCR.EXE SCREENSWCC III Technical Guide4-69Single Duct Reheat Pressure Independent Globals & Setup ScreensFigure 4-44: Single Duct Reheat -

Page 312 - Running the SCUSCR Program

I. INTRODUCTIONWCC III Technical GuideI-16 WCC III M-Comm Board (SS5007)The WCC III M-Comm Board is located inside of the WCC III - MCD case to provid

Page 313 - Controller Overview

WCC III Technical Guide4-704. SCUSCR.EXE SCREENS

Page 314 - Constant Volume Overview

5. WCCUtility.exe Screens5. WCCUtility.exe ScreensWCC III

Page 315 - SCUSCR.EXE Screens Index

TABLE OF CONTENTSSECTION 5: WCCUTILITY.EXE SCREENSHow to Start or Run the WCCUtility.exe Program...

Page 316 - Operation

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-1SECTION 5: WCCUTILITY.EXE SCREENS__________________________________________How to Start or Run the WC

Page 317

WCC III Technical Guide5-2WCCUTILITY.EXE SCREENSIn the Set Password Dialog Screen, enter an “Operator:” identifi cation and a “Code:” or password equal

Page 318 - Modes of Operation

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-3Running the WCCUtility ProgramIP Address:This is the static IP address where the WCC III – MCD is loca

Page 319

WCC III Technical Guide5-4WCCUTILITY.EXE SCREENSWCCUTILITY.EXE OVERVIEWThe WCCUtility.exe program is used to do various WCC III system functions which

Page 320

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-5WCCUTILITY SCREENS UTILITY SCREENThe WccUtility Screen will appear as shown. The Satellite function

Page 321

WCC III Technical Guide5-6WCCUTILITY.EXE SCREENS<Backup System>: This function will backup all of the data from the WCC III system in a fi le nam

Page 322

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-7Save SatelliteThe data which is entered on the following WCC III screens is stored in the memory of th

Page 323

I. INTRODUCTIONWCC III Technical GuideI-17 WCC III M-Comm Loop Expansion BoardThe WCC III M-Comm Loop Expansion Board is used inside of the WCC III -

Page 324

WCC III Technical Guide5-8WCCUTILITY.EXE SCREENSRestore SatelliteIf you would like to restore information from a saved satellite backup fi le, select &

Page 325 - External Trend Logging

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-9If you would like to copy information from one satellite to another, select <Copy Satellite> fr

Page 326 - Force Modes or Overrides

WCC III Technical Guide5-10WCCUTILITY.EXE SCREENSAllow Override Valid StructureYou are given the choice of a YES or a NO answer for this question. Pla

Page 327 - VAV BOX III Status Screen

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-11If you would like to clean one or more satellites of all their data, select <Clean Satellite> f

Page 328

WCC III Technical Guide5-12WCCUTILITY.EXE SCREENSIf you would like to save satellites as, select <Save Satellite As> from the WccUtility Menu. T

Page 329

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-13 SATELLITE RESET LOGTo view satellites that have been reset recently, select <Satellite Reset Lo

Page 330

WCC III Technical Guide5-14WCCUTILITY.EXE SCREENS SATELLITE COMM LOST LOGTo view satellite information regarding lost communication, select <Comm

Page 331

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-15 SATELLITE COMM ERROR LOGTo view satellite communication errors, select <Comm Error Log> from

Page 332 - VAV BOX III Setpoint Screen

WCC III Technical Guide5-16WCCUTILITY.EXE SCREENSIf you would like to view who has accessed the WCC III system and on what dates and times the system

Page 333

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-17To deselect entries you highlighted, click <Clear Selection>. To refresh the screen’s data, cli

Page 334

Form: WCC3MASTER-ALL-01B Copyright October 2013 WattMaster Controls, Inc. WattMaster Controls, Inc. assumes no responsibility for errors or omissi

Page 335 - VAV BOX Globals Screen

I. INTRODUCTIONWCC III Technical GuideI-18Accessory Boards - Power and Switchable Comm Power and Switchable Comm Board The Power and Switchable Comm B

Page 336

WCC III Technical Guide5-18WCCUTILITY.EXE SCREENSTo deselect entries you highlighted, click <Clear Selection>. To refresh the screen’s data, cli

Page 337 - VAV Box Control Method

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-19To deselect entries you highlighted, click <Clear Selection>. To refresh the screen’s data, cli

Page 338

WCC III Technical Guide5-20WCCUTILITY.EXE SCREENS SYSTEM EVENT LOGIf you would like to view communication connections and closures in the WCC III sy

Page 339

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-21Comm Error Log ScreenCOMM ERROR LOGIf you would like to view MCD communications errors, select <Co

Page 340

WCC III Technical Guide5-22WCCUTILITY.EXE SCREENSIf you would like to backup all information in the WCC III system, select <Backup System> from

Page 341

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-23If you would like to backup all satellite data fi les into a single fi le named WCC3SATELLITES.XML, sel

Page 342

WCC III Technical Guide5-24WCCUTILITY.EXE SCREENS BACKUP GLOBALSIf you would like to backup all satellite global fi les (analog and binary) into a si

Page 343

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-25 BACKUP SELECTIVESIf you would like to perform a selective backup of certain fi les, select <Back

Page 344 - VAVBOX II Globals Screen

WCC III Technical Guide5-26WCCUTILITY.EXE SCREENSIf you would like to perform a system restore, select <Restore System> from the WccUtility Menu

Page 345

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-27 RESTORE SATELLITESIf you would like to perform a satellite restore, select <Restore Satellites

Page 346

I. INTRODUCTIONWCC III Technical GuideI-19Accessory Boards - Global Bridge Global Bridge Board (SS5012)The WCC II to WCC III Global Bridge Board provi

Page 347 - Pressure Independent

WCC III Technical Guide5-28WCCUTILITY.EXE SCREENS RESTORE GLOBALSIf you would like to perform a global restore, select <Restore Globals> from

Page 348

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-29 RESTORE SELECTIVESIf you would like to perform a selective restore, select <Restore Selectives

Page 349

WCC III Technical Guide5-30WCCUTILITY.EXE SCREENS COMM TESTIf you would like to check communications to and from satellites on a jobsite, select <

Page 350

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-31 CONVERTING FILESThe new WCC III system can use the same data fi les as the old WCC II system, but t

Page 351

WCC III Technical Guide5-32WCCUTILITY.EXE SCREENSConvert Files ScreenConvert File Cross Reference TableNew WCC III Filename Old WCC II Filename File D

Page 352

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-33Other WCC II Data Files that are not used by the WCC III System:Old WCC IIFilenameFile DetailsSE_DESC

Page 353

WCC III Technical Guide5-34WCCUTILITY.EXE SCREENSBackTask Created DAT Files (cont.)DutyCycleSchedule.datThis data fi le contains all of the actual data

Page 354 - Dependent Screens

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-35ProportionalReset.datThis data fi le contains all of the actual data that is used in the user-programm

Page 355

WCC III Technical Guide5-36WCCUTILITY.EXE SCREENS GLOBAL MATHAfter the newly converted WCC III data fi les have been transferred to the WCC III - MCD

Page 356

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-37 UPLOAD FILEIf you would like to transfer a fi le, select <Upload File> from the WccUtility Me

Page 357

I. INTRODUCTIONWCC III Technical GuideI-20Fiber Optic ConverterIntroduction to Fiber OpticsIn recent years it has become apparent that fi ber-optics ar

Page 358

WCC III Technical Guide5-38WCCUTILITY.EXE SCREENS DOWNLOAD FILEIf you would like to download a fi le, select <Download File> from the WccUtilit

Page 359

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-39SET GLOBAL MAP VIEW AND BRIDGE MAPOverviewThe “WCC II to WCC III Global Bridge” board provides a mean

Page 360

WCC III Technical Guide5-40WCCUTILITY.EXE SCREENSSET GLOBAL MAP VIEWFrom the WCCUtility.EXE program there are two choices for the “WCC II to WCC III G

Page 361 - Independent Screens

WCCUTILITY.EXE SCREENSWCC III Technical Guide5-41SET BRIDGE MAPFrom the WccUtility.exe program there are two choices for the “WCC II to WCC III Global

Page 362

WCC III Technical Guide5-42WCCUTILITY.EXE SCREENS

Page 363

6. Tenant Override 6. Tenant Override ProgramProgramWCC III

Page 364

TABLE OF CONTENTSSECTION 6: TENANT OVERRIDE PROGRAMWCC III Installation Software - DM1WC011-01X ... 6-1WCC II

Page 365

WCC III Technical Guide6-16. TENANT OVERRIDE PROGRAM SECTION 6: TENANT OVERRIDE PROGRAM (SS5024)____________________________________________________

Page 366

6-26. TENANT OVERRIDE PROGRAMWCC III Technical GuideStep 5: The screen will ask you to click the <Next> button to begin installation. After ag

Page 367

WCC III Technical Guide6-36. TENANT OVERRIDE PROGRAMInstalling the ProgramWCC III Tenant Override Installation Software - DM1WC013-01XPlease note: Y

Page 368 - VAV BOX Type 4 Screens

I. INTRODUCTIONWCC III Technical GuideI-21Fiber Optic ConverterFigure I-17: The PL102334 FOSTC Fiber Optic Adapter Board Shown in a Typical Applicati

Page 369

6-46. TENANT OVERRIDE PROGRAMWCC III Technical GuideHow to Start or Run the TenantOverride.exe Program (SS5024) The TenantOverride.exe shortcut icon

Page 370 - VAV BOX Type 5 Screens

WCC III Technical Guide6-56. TENANT OVERRIDE PROGRAMTenant Override Rquesthave access to the WCCIII – MCD and you click <OK> then this connecti

Page 371

6-66. TENANT OVERRIDE PROGRAMWCC III Technical GuideNotes

Page 372 - VAV BOX Type 6 Screens

7. TenantReport.exe7. TenantReport.exeProgramProgramWCC III

Page 373

TABLE OF CONTENTS SECTION 7: TENANTREPORT.EXE PROGRAMHow to Start or Run theTenantReport.exe Program ...7-1Running the Program .

Page 374 - VAV BOX Type 7 Screens

WCC III Technical Guide7-17. TENANTREPORT.EXE SCREENS SECTION 7: TENANTREPORT.EXE PROGRAM (SS5025)The TenantReport.exe program is used in conjunctio

Page 375

7-27. TENANTREPORT.EXE SCREENSWCC III Technical GuideThe WCC3.exe program has a Tenant Override setup screen that also has to be fi lled out in order

Page 376 - VAV BOX Type 8 Screens

WCC III Technical Guide7-37. TENANTREPORT.EXE SCREENSPrinting Tenant Override ReportsLight Override Total:Heat Override Total:A/C Override Total:The

Page 377

7-47. TENANTREPORT.EXE SCREENSWCC III Technical GuideRunning the Program

Page 378 - VAV BOX Type 9 Screens

8. Trendlog.exe8. Trendlog.exeProgramProgramWCC III

Page 379

I. INTRODUCTIONWCC III Technical GuideI-22 TUC/ RTU CONTROLLER BOARDS TYPES TUC-2R Controller - ( OE320)The TUC-2R Controller is a Terminal Unit Contr

Page 380

TABLE OF CONTENTS SECTION 8: TRENDLOG.EXE PROGRAMOverview ... 8-1How to Start or Run the WCC3Trend

Page 381 - 5. WCCUtility.exe Screens

WCC III Technical Guide8-18. TRENDLOG.EXE PROGRAM SECTION 8: TRENDLOG.EXE PROGRAM (SS5028)The WCC3Trendlog.exe program is to be used if extensive lo

Page 382

8-28. TRENDLOG.EXE PROGRAMWCC III Technical GuideThe TrendManager1 Screen will list all of the various user-programmed trend log programs that have

Page 383

WCC III Technical Guide8-38. TRENDLOG.EXE PROGRAMPrinting Tenant Override ReportsIP Address:The IP Address fi eld is the IP address of the WCC III - M

Page 384

8-48. TRENDLOG.EXE PROGRAMWCC III Technical GuideSort by Description:The <Sort by Description> icon button will rearrange the way the user-prog

Page 385

WCC III Technical Guide8-58. TRENDLOG.EXE PROGRAMSet Trend Log Program Dialog The “Set Trend Log Program Dialog” is a user programming setup box that

Page 386 - WCCUtility Program Overview

8-68. TRENDLOG.EXE PROGRAMWCC III Technical GuideFilename:The Filename is the actual fi le name on the end user’s computer that the end user or contra

Page 387 - Main Utility Screen

WCC III Technical Guide8-78. TRENDLOG.EXE PROGRAMThe “Maximum Value” box is the upper limit set point for this trend log source data. The default val

Page 388

8-88. TRENDLOG.EXE PROGRAMWCC III Technical GuideView Trendlog DataOnce data has started to collect from the points that were chosen to trend log, th

Page 389 - Save Satellite Screen

WCC III Technical Guide8-98. TRENDLOG.EXE PROGRAMViewing Trendlog DataClose:The <Close> button will close the window and return to the list of

Page 390 - Restore Satellite Screen

I. INTRODUCTIONWCC III Technical GuideI-23TUC/RTU Controller Boards - TUC-2RFigure I-18: The TUC-2R Controller

Page 391 - Copy Satellite Screen

8-108. TRENDLOG.EXE PROGRAMWCC III Technical Guide

Page 392

10. RS-485 Communications 10. RS-485 Communications and Troubleshootingand TroubleshootingWCC III

Page 393 - Clean Satellite Screen

TABLE OF CONTENTS SECTION 10: RS-485 COMMUNICATIONS ANDTROUBLESHOOTINGWCC III – MCD and SAT III TypeControllers “RS-485 Network Loop” Communications

Page 394 - Save Satellite As Screen

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-1SECTION 10: RS-485 COMMUNICATIONS ANDTROUBLESHOOTING__________________________________________WCC

Page 395 - Satellite Reset Log Screen

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-2SAT 3C/D/F TUC Loop CommunicationsThe SAT 3C/D/F TUC Loop CommunicationsThe software that is in th

Page 396 - SATELLITE COMM LOST LOG

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-3RS-485 Wire Considerations The RS-485 wire specifi cations are generally a stranded 18- gauge, 2-wi

Page 397 - SATELLITE COMM ERROR LOG

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-4Figure 10-4: Power and Switchable RS-485 Communications Board Application DrawingPower and Switc

Page 398 - System Log Screen

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-524VAC Power Wiring ConsiderationsYou do not have to use the 24VAC connections on the Power and Swi

Page 399 - Alarm Log Screen

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-6Wiring of the WCC III RS-485 communications loop as represented in Figure 10-5 is not recommend fo

Page 400 - Data Log Screen

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-7 Wiring of the WCC III RS-485 communications loop as represented in Figure 10-6 is recommended for

Page 401 - Acknowledge Alarm Log Screen

I. INTRODUCTIONWCC III Technical GuideI-24TUC/RTU Controller Boards - TUC-5R/TUC-5R+ TUC-5R (TUC-5R+) Controller - ( OE330 and OE331)The TUC-5R (late

Page 402 - System Event Log Screen

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-8Lightning SuppressionLightning SuppressionLightning is an act of nature and as such cannot be pred

Page 403 - COMM ERROR LOG

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-9MCD Troubleshooting with a Digital VoltmeterTroubleshooting of the WCC III system RS-485 satellite

Page 404 - Backup System Screen

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-10SAT III Troubleshooting with a Digital VoltmeterSAT III Communications Troubleshooting with a Dig

Page 405 - Backup Satellites Screen

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-11The voltage measurements in Figure 10-11 are approximate voltages. These voltage measurements are

Page 406 - Backup Globals Screen

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-12SAT 3C/D/F Troubleshooting with a Digital VoltmeterFigure 10-13: Typical SAT 3C/D/F TUC RS-485 S

Page 407 - Backup Selectives Screen

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-13SAT 3P Troubleshooting with a Digital VoltmeterFigure 10-15: Typical SAT 3P TUC RS-485 Satellite

Page 408 - Restore System Screen

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-14TUC-2R Troubleshooting with a Digital VoltmeterFigure 10-17: Typical TUC-2R RS-485 TUC Communica

Page 409 - Restore Satellites Screen

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-15TUC-2R Troubleshooting with a Digital VoltmeterFigure 10-19: Typical TUC-2R RS-485 TUC Communica

Page 410 - Restore Globals Screen

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-16VAVZ II Troubleshooting with a Digital VoltmeterFigure 10-21: Typical VAVZ II RS-485 TUC Communi

Page 411 - Restore Selectives Screen

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-17The voltage measurements in Figure 10-23 are approximate voltages. Older TUC-5R Controllers used

Page 412 - Comm Test Screen

I. INTRODUCTIONWCC III Technical GuideI-25TUC/RTU Controller Boards - RTU-17 RTU-17 CONTROLLER - ( OE310)The RTU-17 Controller is typically used to co

Page 413 - CONVERTING FILES

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-18TUC-5R Troubleshooting with a Digital VoltmeterFigure 10-25: Typical TUC-5R RS-485 TUC Communica

Page 414 - Convert Files Screen

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-19RTU-17 Troubleshooting with a Digital VoltmeterFigure 10-27: Typical RTU-17 RS-485 TUC Communica

Page 415 - BackTask Created Files

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-20RTU-17 Troubleshooting with a Digital VoltmeterFigure 10-29: Typical RTU-17 RS-485 TUC Communic

Page 416

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-21Global Bridge Troubleshooting with a Digital VoltmeterFigure 10-31: Typical Global Bridge RS-485

Page 417

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-22Replacing RS-485 Driver Chip(s) on SAT IIIFigure 10-33: Replacing the RS-485 Driver Chip(s) on t

Page 418 - Global Math Screen

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-23Figure 10-35: Replacing the RS-485 Driver Chip(s) on the TUC-5R / TUC-5R+ ControllerYou must fi r

Page 419 - Upload File Screen

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-24You must fi rst disconnect the 24VAC power and then disconnect the three-wire RS-485 communication

Page 420 - Download File

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-25Figure 10-38: Replacing the RS-485 Driver Chip(s) on the Global Bridge ControllerReplacing RS-48

Page 421

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-26Replacing RS-485 Driver Chips on the SAT 3C/D/FFigure 10-39: Replacing the RS-485 Driver Chip(s)

Page 422 - Set Global Map View Screen

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-27Replacing RS-485 Driver Chips on the WCC3 Binary Input BoardFigure 10-40: Replacing the RS-485 D

Page 423 - Set Bridge Map Screen

I. INTRODUCTIONWCC III Technical GuideI-26VAVZ II ControllerVAVZ II ControllerWattMaster Controls, Inc. has a new VAV Zone Controller available. This

Page 424

10. RS-485 COMMUNICATIONSWCC III Technical Guide10-28Replacing RS-485 Driver Chips on the WCC3 V-Out Relay BoardFigure 10-41: Replacing the RS-485 Dr

Page 425 - 6. Tenant Override

11. WCC III Alarming11. WCC III AlarmingWCC III

Page 426 - TENANT OVERRIDE PROGRAM

TABLE OF CONTENTSSECTION 11: WCC III ALARMINGAlarm Call-Out ...11-1Analog Alarm Limit ...

Page 427

11. WCC III ALARMINGWCC III Technical Guide11-1SECTION 11: WCC III ALARMING__________________________________________Alarm Call-OutThe WCC III - MCD

Page 428 - Installing the Program

WCC III Technical Guide11-211. WCC III ALARMINGThe alarm limits along with the alarm type and alarm message numbers are assigned on this screen (see

Page 429 - Software - DM1WC013-01X

11. WCC III ALARMINGWCC III Technical Guide11-3Satellite SOS AlarmIf the Master Communications Device loses communications with a satellite controlle

Page 430 - Running the Program

WCC III Technical Guide11-411. WCC III ALARMINGHow to Send a Text Message to a Cellular Phone via an Email from the WCC III System Most cellular tele

Page 431 - Tenant Override Request

11. WCC III ALARMINGWCC III Technical Guide11-5Analog Global AlarmsEach one of the 256 Analog Globals can have an analog type of alarm that can be as

Page 432

WCC III Technical Guide11-611. WCC III ALARMINGOn the main screen of the WCC3.exe program there is choice fi eld for the Alarm Messages Screen. Upon

Page 433 - 7. TenantReport.exe

11. WCC III ALARMINGWCC III Technical Guide11-7On the main screen of the WCC3.exe program there is choice fi eld for the Alarm Summary Screen. Upon e

Page 434 - TENANTREPORT.EXE PROGRAM

I. INTRODUCTIONWCC III Technical GuideI-27Part Numbers - Boards WCC III RELATED PART NUMBERSBOARD NAME LOWER LEVE

Page 435 - (SS5025)

WCC III Technical Guide11-811. WCC III ALARMINGThe WCC3 System Parameters Screen is used to enable, disable, and setup E-mailing of Alarms for the WC

Page 436

11. WCC III ALARMINGWCC III Technical Guide11-9Authentication:For e-mail servers that require authentication, this fi eld should be set to Auto, Login

Page 437

WCC III Technical Guide11-1011. WCC III ALARMINGPort NumberThe WCC3.exe program opens a two-way, secure communications port that then allows for comm

Page 438

11. WCC III ALARMINGWCC III Technical Guide11-11OperatorAll WCC3 users or “Operators” should have their name entered in this fi eld. This is for secur

Page 439 - 8. Trendlog.exe

WCC III Technical Guide11-1211. WCC III ALARMING

Page 440 - TRENDLOG.EXE PROGRAM

12. WCC III Installation 12. WCC III Installation GuideGuideWCC III

Page 441 - Overview

TABLE OF CONTENTSSECTION 12: WCC III INSTALLATION GUIDEWCC III System Requirements ... 12-1MCD Basic Operating Conditions ...

Page 442

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-1SECTION 12: WCC III INSTALLATION GUIDE__________________________________________WCC III Syst

Page 443

WCC III Technical Guide12-212. WCC III INSTALLATION The WCC III – MCD Basic Operating ConditionsThe WCC III - MCD must be kept in a clean and dry area

Page 444

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-3Figure 12-2: Wall mounting instructions for the WCC III – MCDNOTES: Use approved anchors wh

Page 445

Part NumbersPART DESCRIPTIONWCC3PART NUMBERVCB-X Controller OE335-23-VCBX-AVCB-X 12 Relay Expansion Module OE358-23E-12R-AVCB-X Expansion Module 1 O

Page 446

I. INTRODUCTIONWCC III Technical GuideI-28Part Numbers - Sensors10 K Type Thermistor Sensors Sensor Description WM “OE” PAR

Page 447

WCC III Technical Guide12-412. WCC III INSTALLATION WCC III – MCD Internet Access The most common question asked is: Why does the WCC III – MCD comput

Page 448 - Viewing Trendlog Data

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-5In a typical WCC III - MCD networking setup, internet access is through a DSL or Cable modem.

Page 449

WCC III Technical Guide12-612. WCC III INSTALLATION Supported NetworksOnly Microsoft based networks are currently supported by the WCC III system. An

Page 450

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-7The WCC III System RS-485 Communication WiringThe WCC III - MCD can communicate with up to 23

Page 451 - 10. RS-485 Communications

WCC III Technical Guide12-812. WCC III INSTALLATION Figure 12-5: The WCC III typical system architecture with POWER and SWITCHABLE COMM boardsFigure

Page 452 - TROUBLESHOOTING

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-9The wire that makes up the communication loop should be shielded. Shielded cable has an alum

Page 453 - Communications

WCC III Technical Guide12-1012. WCC III INSTALLATION Satellite ControllerMounting in an EnclosureThe satellite controllers are designed to mount in an

Page 454 - The SAT 3C/D/F TUC Loop

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-1187SAT ADDRESS2148A3 WIRE ROOMSENSORWILLNOTREQUIRE A LOAD RESISTOR WHEN SETFOR A 1 VOLT INPUT

Page 455

WCC III Technical Guide12-1212. WCC III INSTALLATION Figure 12-9: A typical SAT 3C/D/F controller in a single electrical panel (120-VAC powered) Figu

Page 456

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-13Figure 12-11: A typical SAT 3C/D/F controller in a (dual) quad electrical panel (120-VAC po

Page 457

I. INTRODUCTIONWCC III Technical GuideI-29 HSS Cables Five conductor cable with shield. This cable also has 6 position female Mini-Fit connectors at b

Page 458 - Wrong Communications Wiring

WCC III Technical Guide12-1412. WCC III INSTALLATION If you order the satellite controller in an enclosure, the factory will provide and install the w

Page 459

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-15 Satellite Controllers - General Dimensions87SAT ADDRESS2148A 3 WIRE ROOM SENSOR WILL NOTREQ

Page 460 - Lightning Suppression

WCC III Technical Guide12-1612. WCC III INSTALLATION SAT III Controller—LED Information (SS5003)The SAT III Controller has 24 LEDs on the cover of the

Page 461

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-17SAT III Controller — Connection PointsAll of the external SAT III connection points are sing

Page 462

WCC III Technical Guide12-1812. WCC III INSTALLATION C 1 to C 8 ConnectionsThe eight “C” connection points of the SAT III controller were originally c

Page 463

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-19Addressing (Numbering) of SAT III ControllersThe WCC III system can have up to 239 SAT III c

Page 464

WCC III Technical Guide12-2012. WCC III INSTALLATION Care must be taken to ensure that two SAT III controllers do not have the same address. When this

Page 465

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-21SAT III Relay OutputsThe standard SAT III controller is capable of providing 16 binary (on/o

Page 466

WCC III Technical Guide12-2212. WCC III INSTALLATION The terminals for the binary outputs are found at the lower left- hand corner of the SAT III cont

Page 467

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-23The “COM” or common connection point can either be connected to 24 VAC / 24 VDC or GROUND.

Page 468

I. INTRODUCTIONWCC III Technical GuideI-30Part Numbers - Cables and WireActuator CablesThis modular cable has 6 position phone jack connectors at both

Page 469

WCC III Technical Guide12-2412. WCC III INSTALLATION Proportional-Integral (PI) Output BoardThe Proportional-Integral (PI) Board is a separate integra

Page 470

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-25The DC voltage range along with the ramp speed is set at the PI board. The ramp speed can be

Page 471

WCC III Technical Guide12-2612. WCC III INSTALLATION If you want to test the ramp speed, disconnect all wires from the “HEAT,” “COM1,” “COOL,” and “CO

Page 472

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-27Sequence of OperationWhen the SAT III controller makes COM to H, 24 VAC is supplied to the “

Page 473

WCC III Technical Guide12-2812. WCC III INSTALLATION The “Old” SAT II Type Binary Input with Time Delay Board - Connection PointsAll external connecti

Page 474 - Replacing RS-485 Driver Chips

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-29The “Old” SAT II Type Binary Input with Time Delay Board Installation and MountingIt is impo

Page 475

WCC III Technical Guide12-3012. WCC III INSTALLATION WCC III Binary Input with Time Delay Board – Connection Points (SS5006)All external WCC III Binar

Page 476

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-3187SAT ADDRESS2148A3WIREROOMSENSORWILLNOTREQUIRE A LOAD RESISTORWHEN SETFOR A 1 VOLTINPUT.Wat

Page 477

WCC III Technical Guide12-3212. WCC III INSTALLATION Figure 12-27: The WCC III Binary Input with Time Delay board typical wiring diagram – Alternativ

Page 478

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-33THE VA RATING FOR THE WCC3 BINARY INPUT BOARD IS 5 VA.Figure 12-28: The WCC III Binary Inpu

Page 479

1. General Instructions1. General InstructionsWCC III

Page 480

WCC III Technical Guide12-3412. WCC III INSTALLATION SAT III V-OutThe SAT III controller has the capability of providing 8 analog output signals which

Page 481 - 11. WCC III Alarming

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-35Figure 12-29: The “old” SAT II Type V-Out BoardCONNECTIONS #1 THRU #8 TO THE OLD SAT II TYP

Page 482 - WCC III ALARMING

WCC III Technical Guide12-3612. WCC III INSTALLATION The “Old” SAT II Type V-Out Board - Connection PointsAll external “old” SAT II type V-Out board c

Page 483

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-37The connecting HSS cable is available in 1-ft, 1½-ft, 3-ft, 25-ft, 40-ft, 80-ft, and 120-ft

Page 484 - Run Time Alarm

WCC III Technical Guide12-3812. WCC III INSTALLATION Figure 12-31: The WCC III V-Out Relay Board (OE430-01)WCC III V-Out Relay Board Connection Point

Page 485 - Alarm Logs

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-39RLY 1 to RLY 8 COM – N.O. Connections These are the eight Normally Open relay contacts of th

Page 486 - Text Messaging Alarms

WCC III Technical Guide12-4012. WCC III INSTALLATION Figure 12-33: V-Out Relay Board typical wiring diagram for Binary Output use with the HSS connec

Page 487

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-4187SAT ADDRESS2148A 3 WIRE ROOM SENSO RW ILL NOTREQUIRE A LOAD RESISTORWHEN SETFOR A 1 VOLT I

Page 488 - ALARM MESSAGES SCREEN

WCC III Technical Guide12-4212. WCC III INSTALLATION JO1 corresponds to ATI #1 input, JO2 corresponds to ATI #2 input, JO3 corresponds to ATI #3 input

Page 489

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-43Temperature SensorsOlder SAT II Type SensorsSENSOR DESCRIPTION WM “OE

Page 490 - SYSTEM PARAMETERS SCREEN

TABLE OF CONTENTSSECTION 1: GENERAL INSTRUCTIONSWCC III FEATURES AND MAINTENANCE ...1-1“Where To Find” Features ...

Page 491

WCC III Technical Guide12-4412. WCC III INSTALLATION 0 - 1, 0 – 5, 0 - 10 VDC, and Thermistor Type SensorsThe SAT III controller can accept a 0-1VDC,

Page 492

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-45The following table shows the required load resistor, Data Pattern, 0 % and 100 % programmed

Page 493

WCC III Technical Guide12-4612. WCC III INSTALLATION 4-to-20 Milli-Amp Current SensorsThe connection of a 4-to-20 milli-amp sensor to a SAT III contr

Page 494

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-47When programming the Analog Input Screen, the zero percent scale value is the value when 0 m

Page 495 - 12. WCC III Installation

WCC III Technical Guide12-4812. WCC III INSTALLATION Figure 12-39: Temperature Resistance Voltage for Type III 10K Thermistor SensorThermistor Resisto

Page 496

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-49SAT 3C – WCC III Interface to TUC/RTU ControllersFigure 12-40: SAT 3C ControllerThe system

Page 497

WCC III Technical Guide12-5012. WCC III INSTALLATION SAT 3C Controller - Connections pointsAll of the external SAT 3C connection points are single-tab

Page 498 - Conditions

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-51Addressing the SAT 3CThe address dip switches are additive; that is to say placing switches

Page 499

WCC III Technical Guide12-5212. WCC III INSTALLATION For example the following Satellite Addresses will not work as a SAT 3C starting address. 1, 2, 3

Page 500 - WCC III - MCD Internet Access

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-53the word “TEST” into one of the control point values in the TUC/RTU controller to check the

Page 501

1. GENERAL INSTRUCTIONSWCC III Technical Guide1-1SECTION 1: GENERAL INSTRUCTIONS____________________________________________________“Where To Find”

Page 502

WCC III Technical Guide12-5412. WCC III INSTALLATION The RTU-17 controller is an application-specifi c controller. Please see the application specifi

Page 503 - RS-485 Communication Wiring

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-55There are 4 versions of the TUC-5R type controller, three of which are still currently suppo

Page 504

WCC III Technical Guide12-5612. WCC III INSTALLATION The current TUC-5R+ controller is an application-specifi c controller. Please see the application

Page 505

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-57SAT 3D – WCC III Interface to TUC/RTU Controllers (SS5005)The system architecture for the WC

Page 506 - Satellite Controller

WCC III Technical Guide12-5812. WCC III INSTALLATION Addressing the SAT3DFigure 12-46: SAT 3D Address Switch locationThe address dip switches are add

Page 507

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-59If a satellite controller was accidentally addressed #8, there will be a satellite number mi

Page 508

WCC III Technical Guide12-6012. WCC III INSTALLATION Addressing (Numbering) of the TUC controllers that are connected to the SAT 3DThere can be up to

Page 509

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-61How to Address TUC-2R and TUC-5R when connecting them to a Sat 3DEach SAT 3d physically take

Page 510 - Satellite Controller Wiring

WCC III Technical Guide12-6212. WCC III INSTALLATION SAT 3F – WCC III Interface to TUC/VAVZ II Controllers (SS5016)The system architecture for the WCC

Page 511

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-63Addressing the SAT3FFigure 12-48: SAT 3F Address Switch locationThe address dip switches ar

Page 512 - SAT III LED Descriptions

1. GENERAL INSTRUCTIONSWCC III Technical Guide1-2Service Item As Req’dEvery WkEvery MoEvery 3 MoEvery 6 MoEvery 12 MoSave satellite data to diskXXTe

Page 513 - SAT III Connection Points

WCC III Technical Guide12-6412. WCC III INSTALLATION If a satellite controller was accidentally addressed #8, there will be a satellite number missing

Page 514

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-65Addressing (Numbering) of the TUC controllers that are connected to the SAT 3FThere can be u

Page 515 - SAT III Addressing

WCC III Technical Guide12-6612. WCC III INSTALLATION How to Address VAVZ II when connecting them to a Sat 3FEach SAT 3F physically takes up 4 plain Sa

Page 516

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-67The current TUC-2R controller is an application-specifi c controller. Please see the applica

Page 517 - SAT III Relay Outputs

WCC III Technical Guide12-6812. WCC III INSTALLATION G5L-114P-PS24VDCCONTACT:UL / CSA 5A250VACOMRONOMRONG5L-114P-PS24VDCCONTACT:UL / CSA 5A250VACG5L-1

Page 518 - 12345678

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-69This Damper actuator uses a 4-position handset modular plug to connect to the TUC-2R control

Page 519

WCC III Technical Guide12-7012. WCC III INSTALLATION How to Start or Run the WCC3.exe Program (SS5021)The WCC3.exe shortcut icon should have been inst

Page 520

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-71The Remote Access Dialog Box will allow you to enter multiple WCC III – MCD IP addresses bas

Page 521 - PI Board Connection Points

WCC III Technical Guide12-7212. WCC III INSTALLATION Left-click <Cancel> to return to the Connection Dialog Box that was fi rst displayed. The

Page 522

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-73 "UP"Button"DOWN" Button "SELECT" "HOLD""ROTA

Page 523

1. GENERAL INSTRUCTIONSWCC III Technical Guide1-3Recommended Data Entry ProcedureWhen setting up an WCC III system, the screens can be programmed in

Page 524

WCC III Technical Guide12-7412. WCC III INSTALLATION SELECTDESELECTCHECKHEART BEATUP/DOWN ITEM SELECTSUBMENU UP SELECTSUBMENU DOWN SELECTThe LCD Chara

Page 525

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-75CrystalfontzRx: 0.0 Down lTx: 0.0 UP 0IP PacketAn IP packet is the formatted unit of d

Page 526

WCC III Technical Guide12-7612. WCC III INSTALLATION Crystalfontz OPTIONSHeartbeatOptions Menu – Heart Beat Selection Press eithe

Page 527

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-77 Crystalfontz ContrastOn BrightnessOptions Menu – CfontzPacket Submenu – On Brig

Page 528

WCC III Technical Guide12-7812. WCC III INSTALLATION The WCC III - MCDThe WCC III - MCDOverviewThe WCC III – MCD was converted from the Windows XP ope

Page 529

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-79Using the MCD-Menu ProgramUsing the MCD-Menu ProgramOverviewThe default administration usern

Page 530 - SAT III V-Out Board

WCC III Technical Guide12-8012. WCC III INSTALLATION Using the MCD-Menu ProgramStep 3: Pressing the “enter” key or the “d” key will result in the nex

Page 531 - Old SAT II Type V-Out Board

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-81Using the MCD-Menu ProgramAfter you have entered in all of the required IP addresses, subnet

Page 532 - WCC III V-Out Relay Board

WCC III Technical Guide12-8212. WCC III INSTALLATION Using the MCD-Menu ProgramCopying fi le: /home/wcciii/.wine/drive_c/Backtask/ProportionalReset.dat

Page 533

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-83Using the MCD-Menu ProgramCopying fi le: /home/wcciii/.wine/dosdevices/d:/TenantOverrideRecor

Page 534 - Connection Points (SS5008)

1. GENERAL INSTRUCTIONSWCC III Technical Guide1-4The SAT III controller has two sets of 8 small switches on its front cover labeled L1-L16. Switches

Page 535 - Installation and Mounting

WCC III Technical Guide12-8412. WCC III INSTALLATION Using the MCD-Menu ProgramRestart LCD Driver (Choice #6)On the front of the WCC III – MCD, there

Page 536

12. WCC III INSTALLATION GUIDEWCC III Technical Guide12-85Using the MCD-Menu ProgramShutdown MCD (Choice 10)There are times that occur when you would

Page 537 - SAT III Analog Inputs

WCC III Technical Guide12-8612. WCC III INSTALLATION

Page 538

13A. WCC III - MCD 13A. WCC III - MCD Installation GuideInstallation GuideWCC III

Page 539 - Temperature Sensors

TABLE OF CONTENTSSECTION 13A: WCC III - MCD INSTALLATION GUIDEWCC III System Requirements ...13A-1The WCC III – MCD Basic Operating Cond

Page 540

13. WCC III - MCD INSTALLATION GUIDEWCC III Technical Guide13A-1SECTION 13A: WCC III - MCD INSTALLATION GUIDE________________________________________

Page 541 - Analog Input Values

WCC III Technical Guide13A-213. WCC III - MCD INSTALLATION GUIDEThe WCC III – MCD Basic Operating ConditionsThe WCC III - MCD must be kept in a clean

Page 542

13. WCC III - MCD INSTALLATION GUIDEWCC III Technical Guide13A-3NOTE: For Windows users, the end users are responsible for maintaining their system’s

Page 543 - Thermistor Sensors

WCC III Technical Guide13A-413. WCC III - MCD INSTALLATION GUIDEIn a typical WCC III - MCD networking setup, internet access is through a DSL or Cable

Page 544

13. WCC III - MCD INSTALLATION GUIDEWCC III Technical Guide13A-5Mount the WCC III - MCD 4-½ to 5-½ feet off of the ground on a suitable wall, in an ai

Page 545

1. GENERAL INSTRUCTIONSWCC III Technical Guide1-5 87SAT ADDRE SS2148A 3 WIRE ROOM SENSOR WILL NOTREQUIRE A LOAD RESISTOR WHENSETFOR A 1 VOLT INP UT

Page 546 - SAT 3C Controller

WCC III Technical Guide13A-613. WCC III - MCD INSTALLATION GUIDESystem SetupYou must follow the directions in the order they are given.Set-Up Cable Mo

Page 547 - SAT 3C Addressing

13. WCC III - MCD INSTALLATION GUIDEWCC III Technical Guide13A-7 "UP"Button"DOWN" Button "SELECT" "HOLD"&quo

Page 548

WCC III Technical Guide13A-813. WCC III - MCD INSTALLATION GUIDESELECTDESELECTCHECKHEART BEATUP/DOWN ITEM SELECTSUBMENU UP SELECTSUBMENU DOWN SELECTTh

Page 549

13. WCC III - MCD INSTALLATION GUIDEWCC III Technical Guide13A-9CrystalfontzRx: 0.0 Down lTx: 0.0 UP 0IP PacketAn IP packet is the formatted uni

Page 550 - RTU-17 Controller

WCC III Technical Guide13A-1013. WCC III - MCD INSTALLATION GUIDE Crystalfontz OPTIONSHeartbeatOptions Menu – Heart Beat Selection

Page 551

13. WCC III - MCD INSTALLATION GUIDEWCC III Technical Guide13A-11 Crystalfontz ContrastOn BrightnessOptions Menu – CfontzPacket Submenu –

Page 552

WCC III Technical Guide13A-1213. WCC III - MCD INSTALLATION GUIDEThe WCC III System RS-485 Communication WiringThe WCC III - MCD can communicate with

Page 553 - SAT 3D Controller

13. WCC III - MCD INSTALLATION GUIDEWCC III Technical Guide13A-13Figure 5: The WCC III typical system architecture with POWER and SWITCHABLE COMM boa

Page 554 - SAT 3D Addressing

WCC III Technical Guide13A-1413. WCC III - MCD INSTALLATION GUIDEThe SAT RS-485 communication loop wires are connected to the “R” and “T” and shield t

Page 555

13. WCC III - MCD INSTALLATION GUIDEWCC III Technical Guide13A-15The WCC III - MCDThe WCC III - MCD OverviewThe WCC III – MCD was converted from the W

Page 557

1. GENERAL INSTRUCTIONSWCC III Technical Guide1-6 Analog OutputsAn analog output is a variable DC voltage signal sent from the satellite controller

Page 558 - SAT 3F Controller

WCC III Technical Guide13A-1613. WCC III - MCD INSTALLATION GUIDEUsing the MCD-Menu ProgramUsing the MCD-Menu ProgramOverviewThe default administratio

Page 559 - SAT 3F Addressing

13. WCC III - MCD INSTALLATION GUIDEWCC III Technical Guide13A-17Using the MCD-Menu ProgramStep 3: Pressing the “enter” key or the “d” key will resul

Page 560

WCC III Technical Guide13A-1813. WCC III - MCD INSTALLATION GUIDEUsing the MCD-Menu ProgramAfter you have entered in all of the required IP addresses,

Page 561

13. WCC III - MCD INSTALLATION GUIDEWCC III Technical Guide13A-19Using the MCD-Menu ProgramCopying fi le: /home/wcciii/.wine/drive_c/Backtask/Proportio

Page 562 - How to Address VAVZ II when

WCC III Technical Guide13A-2013. WCC III - MCD INSTALLATION GUIDEUsing the MCD-Menu ProgramCopying fi le: /home/wcciii/.wine/dosdevices/d:/TenantOverri

Page 563

13. WCC III - MCD INSTALLATION GUIDEWCC III Technical Guide13A-21Using the MCD-Menu ProgramRestart LCD Driver (Choice #6)On the front of the WCC III –

Page 564

WCC III Technical Guide13A-2213. WCC III - MCD INSTALLATION GUIDEUsing the MCD-Menu ProgramShutdown MCD (Choice 10)There are times that occur when you

Page 565 - TUC-2R Velocity Sensor

13. WCC III - MCD INSTALLATION GUIDEWCC III Technical Guide13A-23BIOS Screen Setup Information for the Advantech SBC Model PCI-6881 (V1.20 & V1.21

Page 566 - Program (SS5021)

WCC III Technical Guide13A-2413. WCC III - MCD INSTALLATION GUIDEPower Management SetupACPI Function [Enabled]Power Management [User Defi ne]Video

Page 567

13. WCC III - MCD INSTALLATION GUIDEWCC III Technical Guide13A-25WCC III - MCD Linux Base System InstallationWCCIII – MCD Linux Base System Install (S

Page 568

1. GENERAL INSTRUCTIONSWCC III Technical Guide1-7 Binary OutputsA binary output on the SAT III controller is the electronic equivalent of a relay c

Page 569 - WCC III - MCD LCD Display

WCC III Technical Guide13A-2613. WCC III - MCD INSTALLATION GUIDEStep 7: When prompted, you should highlight and select Yes when you’re asked, “Write

Page 570

13B. WCC III - MCD2 13B. WCC III - MCD2 Installation GuideInstallation GuideWCC III

Page 571

TABLE OF CONTENTSSECTION 13B: WCC III - MCD2 INSTALLATION GUIDE__________________________________________Main Differences Between the First Generatio

Page 572

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-1SECTION 13B: WCC III - MCD2 INSTALLATION GUIDE_____________________________________

Page 573 -

WCC III Technical Guide13B-213B. WCC III - MCD INSTALLATION GUIDETable 13B-1: MCD vs. MCD2Main Differences Between MCD and MCD2Main Differences Betwe

Page 574

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-3Table 13B-1, continued: MCD vs. MCD2NOTE 1The fi rst generation WCC III - MCD platfo

Page 575 - Using the MCD-Menu Program

WCC III Technical Guide13B-413B. WCC III - MCD INSTALLATION GUIDEMCD2 DimensionsFigure 1: MCD2 Dimensions In Inches

Page 576

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-5System RequirementsTo accomplish remote communications via the internet, the followi

Page 577

WCC III Technical Guide13B-613B. WCC III - MCD INSTALLATION GUIDEUninterruptable Power SupplyThe WCCIII-MCD2 system is designed to automatically resta

Page 578

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-7RS-485 Communications WiringThe WCC III System RS-485 Communications WiringThe WCCII

Page 579

1. GENERAL INSTRUCTIONSWCC III Technical Guide1-8 Point AddressesA Point Address uniquely identifi es a point within the WCC III system. All point add

Page 580

WCC III Technical Guide13B-813B. WCC III - MCD INSTALLATION GUIDEact of 1990/2009. A minimum of two inches of clearance should be maintained all arou

Page 581

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-9Figure 5: Bottom View - Minimum Mounting Distance ClearanceWCCIII-MCD2 Mounting Req

Page 582

WCC III Technical Guide13B-1013B. WCC III - MCD INSTALLATION GUIDEPower Supply (24VAC) RequirementsThe WCCIII-MCD2 should only be powered by a dedicat

Page 583 - Installation Guide

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-11Initiating the SystemInitiating the SystemThe SAT RS-485 communication loop wires a

Page 584

WCC III Technical Guide13B-1213B. WCC III - MCD INSTALLATION GUIDER & T COMMUNICATIONS LEDsThere are simplistic communication diagnostic LEDs that

Page 585

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-13Serial PortThe Serial port is a 9 Pin “AT – Type” port that is now only used for ex

Page 586

WCC III Technical Guide13B-1413B. WCC III - MCD INSTALLATION GUIDECompact Flash PortThe Compact Flash port on the WCCIII-MCD2 is utilized for insertin

Page 587 - WCC III – MCD Internet Access

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-15The 4 Line by 20 Character LCD screen on the WCCIII-MCD2The CrystalFontz – 4 by 20

Page 588

WCC III Technical Guide13B-1613B. WCC III - MCD INSTALLATION GUIDEWCCIII-MCD2 LCD ScreensSystem TimeThe System Time Info screen displays information o

Page 589 - (supplied by others)

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-17NET LoadThe NET Load info screen displays a real time Ethernet data packet transmit

Page 590 - System Setup

1. GENERAL INSTRUCTIONSWCC III Technical Guide1-9 Time & TimeBThese logical addresses are the actual time on HH:MM (TIME) and minutes-since-midn

Page 591

WCC III Technical Guide13B-1813B. WCC III - MCD INSTALLATION GUIDEBIOS Information For WCCIII-MC2 System Setup

Page 592

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-19BIOS Information For WCCIII-MC2 System SetupBIOS Confi guration for the WCCIII–MCD2T

Page 593

WCC III Technical Guide13B-2013B. WCC III - MCD INSTALLATION GUIDECover Removal of the WCCIII-MCD2

Page 594

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-21Functions of the WCCIII-MCD2WCCIII-MCD2 FunctionsThe main function of the WCCIII-MC

Page 595

WCC III Technical Guide13B-2213B. WCC III - MCD INSTALLATION GUIDEHow to Setup the IP Address on the WCCIII –MCD2 with the mcd-menu ProgramObtain a VG

Page 596

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-23The mcd-menu is straight forward. You can select the desired function by number (1

Page 597

WCC III Technical Guide13B-2413B. WCC III - MCD INSTALLATION GUIDESetup Network Configuration (Choice #1)This sub program will allow you to set the IP

Page 598 - Initiating the System

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-25Setup Time Zone (Choice #2)This function will call the Time Zone confi guration pro

Page 599

WCC III Technical Guide13B-2613B. WCC III - MCD INSTALLATION GUIDECopying fi le: /opt/backtask/Backtask/OperatorCode.datCopying fi le: /opt/backtask/Bac

Page 600

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-27MCD-Menu ProgramRestore BackTask data Files to USB Drive (Choice #4)This subprogram

Page 601

1. GENERAL INSTRUCTIONSWCC III Technical Guide1-10 EA DriverThe EA Driver Mode is “3-point fl oating” control. For example, assume that the H/C contro

Page 602

WCC III Technical Guide13B-2813B. WCC III - MCD INSTALLATION GUIDEMCD-Menu ProgramTest APC UPS Connection (Choice #5)This function will call the apcac

Page 603

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-29MCD-Menu ProgramRestart APC Monitor Server (Choice #6)This function will call the r

Page 604

WCC III Technical Guide13B-3013B. WCC III - MCD INSTALLATION GUIDEReset MCD to Default IP Address (Choice #11)There are times when you may want to res

Page 605

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-31Restart LCD Display (Choice #14)On the front of the WCCIII-MCD2, there is a 4 by 20

Page 606

WCC III Technical Guide13B-3213B. WCC III - MCD INSTALLATION GUIDE12. The administration username will time out after 15 minutes, and you will be requ

Page 607 - BIOS Screen Setup Information

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-33Install-Menu ProgramSetup New CrystalFontz 635 Display (Choice #1)This function wil

Page 608

WCC III Technical Guide13B-3413B. WCC III - MCD INSTALLATION GUIDEClick on “Continue to this website (not recommended)” with the left mouse button.You

Page 609 - Install (SS5019)

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-35You should now see:You will have to click on the “MCD Controls, System, Others, Net

Page 610

WCC III Technical Guide13B-3613B. WCC III - MCD INSTALLATION GUIDELinux-Based FunctionsSet TimeChange the Date, Month, Year, Hour, Minute, and Second

Page 611 - 13B. WCC III - MCD2

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-37Networking – Network Confi gurationThis is to change the IP address, the Gateway, an

Page 612 - SECTION 13B: WCC III - MCD2

1. GENERAL INSTRUCTIONSWCC III Technical Guide1-11 Satellite #1 ANALOG INPUT #1Description: RM 101 Type: AnalogPattern for v

Page 613

WCC III Technical Guide13B-3813B. WCC III - MCD INSTALLATION GUIDENow you should see:Change the IP Address, Netmask, and Broadcast to the addresses fo

Page 614 - New WCCIII-MCD2 Computers

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-39Hostname and DNS ClientClick on “Hostname and DNS Client” with the left mouse butto

Page 615

WCC III Technical Guide13B-4013B. WCC III - MCD INSTALLATION GUIDECommon Linux CommandsCommon Linux Commands that would be helpful to know for the WCC

Page 616 - MCD2 Dimensions

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-41Common Linux Commandspasswd Changes your passwordwrite username Sends a messag

Page 617

WCC III Technical Guide13B-4213B. WCC III - MCD INSTALLATION GUIDEeth0 eth0 is the network Ethernet connection #0 (Default connection) Used in conj

Page 618

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-43The WCC III-MCD2 Remote Serial ConsoleThe WCC III – MCD Remote Serial ConsoleWhy sh

Page 619 - RS-485 Communications Wiring

WCC III Technical Guide13B-4413B. WCC III - MCD INSTALLATION GUIDEThe WCC III-MCD2 Remote Serial ConsoleNull Modem cablePuTTy is a free alternative to

Page 620

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-45The WCC III-MCD2 Remote Serial ConsoleThe COM port properties dialog box now should

Page 621

WCC III Technical Guide13B-4613B. WCC III - MCD INSTALLATION GUIDEThe WCC III-MCD2 Backup/Restore Data WCCIII-MCD2 Backup/Restore Data to and from USB

Page 622 - Power Supply Requirements

13B. WCC III - MCD2 INSTALLATION GUIDEWCC III Technical Guide13B-47On a new installation, you should select the Install WCCIII-MCD2 Release 1.0 menu o

Page 623

1. GENERAL INSTRUCTIONSWCC III Technical Guide1-12 Run Time AlarmThe WCC III system also has the capability of alarming if the total ON time of a bin

Page 624 - Input/Output Connections

WCC III Technical Guide13B-4813B. WCC III - MCD INSTALLATION GUIDETest MemoryWhen selecting the Test Memory option, you should only use this option to

Page 625

14. SAT III Controller 14. SAT III Controller Installation GuideInstallation GuideWCC III

Page 626

14. SAT III Controller Installation GuideWCC III Technical GuideTable of ContentsWattMaster Controls Inc.8500 NW River Park Drive · Parkville , MO

Page 627 - The LCD’s Keypad

14-1 14. SAT III Controller Installation GuideWCC III Technical GuideSAT III IntroductionSAT III General Specifications:The SAT III controller is

Page 628 - WCCIII-MCD2 LCD Screens

14. SAT III Controller Installation GuideWCC III Technical Guide14-2SAT III - SAT II Comparison

Page 629

WCC III Technical Guide 14. SAT III Controller Installation Guide14-3SAT III I/O Terminology

Page 630

14. SAT III Controller Installation GuideWCC III Technical Guide14-4SAT III I/O Layout Sheet

Page 631 - Resetting the WCCIII-MCD2

WCC III Technical Guide 14. SAT III Controller Installation Guide14-5Notes

Page 632

14. SAT III Controller Installation GuideWCC III Technical Guide14-6WCCIII System OverviewOE210TYPICALSPACESENSOR(X8 MAX)ON/OFF RELAYPUMPS, LIGHTS,ET

Page 633 - WCCIII-MCD2 Functions

WCC III Technical Guide 14. SAT III Controller Installation Guide14-7WCCIII System OverviewOE210TYPICALSENSOR(X8)ON/OFF RELAYPUMPS, LIGHTS,ETC.87S

Page 634

2. Initiating the System2. Initiating the SystemWCC III

Page 635 - MCD-Menu Program

14. SAT III Controller Installation GuideWCC III Technical Guide14-8SAT III Analog Input Wiring

Page 636 - (Choice #1)

WCC III Technical Guide 14. SAT III Controller Installation Guide14-9SAT III Analog Input Wiring

Page 637

14. SAT III Controller Installation GuideWCC III Technical Guide14-10SAT III Analog Input Wiring

Page 638

WCC III Technical Guide 14. SAT III Controller Installation Guide14-11SAT III Analog Input Wiring

Page 639

14. SAT III Controller Installation GuideWCC III Technical Guide14-12SAT III Analog Input Wiring

Page 640

WCC III Technical Guide 14. SAT III Controller Installation Guide14-13SAT III Analog Input Wiring

Page 641

14. SAT III Controller Installation GuideWCC III Technical Guide14-14Analog Input ScreenFOR 0-10 VOLT INPUTS

Page 642

WCC III Technical Guide 14. SAT III Controller Installation Guide14-15SAT III Analog Input Wiring

Page 643

14. SAT III Controller Installation GuideWCC III Technical Guide14-16SAT III Control Output Wiring

Page 644 - Install-Menu Program

WCC III Technical Guide 14. SAT III Controller Installation Guide14-17SAT III Analog Output Wiring

Page 645

TABLE OF CONTENTSSECTION 2: INITIATING THE SYSTEMWCC III System Files ... 2-1WCC III Installation Software CDs ...

Page 646

14. SAT III Controller Installation GuideWCC III Technical Guide14-18SAT III Analog Output WiringWCC3 V-Out Relay Board SequenceThere are two modes o

Page 647

WCC III Technical Guide 14. SAT III Controller Installation Guide14-19SAT III Analog Output Wiring87SATADDRESS2148A 3WIRE ROOM SENSOR WILL NOTREQU

Page 648 - Linux-Based Functions

14. SAT III Controller Installation GuideWCC III Technical Guide14-20SAT III Analog Output Wiring

Page 649

WCC III Technical Guide 14. SAT III Controller Installation Guide14-21SAT III Analog Output Wiring

Page 650

14. SAT III Controller Installation GuideWCC III Technical Guide14-22SAT III Binary Input WiringThe new WCC3 Binary Input w/ time delay board provide

Page 651

WCC III Technical Guide 14. SAT III Controller Installation Guide14-23SAT III Binary Input WiringSAT III CONTROLLER87SATADDRESS2148A 3WIRE ROOM SE

Page 652 - Common Linux Commands

14. SAT III Controller Installation GuideWCC III Technical Guide14-24SAT III Binary Input Wiring87SATADDRESS2148A 3WIRE ROOM SENSOR WILL NOTREQUIRE A

Page 653

WCC III Technical Guide 14. SAT III Controller Installation Guide14-25SAT III Binary Input Wiring

Page 654

14. SAT III Controller Installation GuideWCC III Technical Guide14-26Input/Output Terminology+V CONNECTIONSThese eight +V connections supply a DC vol

Page 655

WCC III Technical Guide 14. SAT III Controller Installation Guide14-27SAT III General Installation Information

Page 656 - Null Modem cable

2. INITIATING THE SYSTEMWCC III Technical Guide2-1SECTION 2: INITIATING THE SYSTEM__________________________________________After the satellite contr

Page 657

Form: WCCIII-OE421-01-TGD-01A Printed in the USA January 2011 All rights reserved. Copyright 2011 WattMa

Page 658

15. SAT 3C/D/F 15. SAT 3C/D/F Installation GuideInstallation GuideWCC III

Page 659 - To exit type command :

TABLE OF CONTENTSSECTION 15: SAT 3C/D/F INSTALLATION GUIDESAT 3C/D/F General Specifi cations... 15-1SAT 3C/D/F Benefi ts and Features .

Page 660 - Ubuntu Linux Installation

WCC III Technical Guide15-115. SAT 3C/D/F INSTALLATIONSECTION 15: SAT 3C/D/F INSTALLATION GUIDE__________________________________________SAT 3C/D/F O

Page 661 - 14. SAT III Controller

WCC III Technical Guide15-215. SAT 3C/D/F INSTALLATIONSAT 3C/D/F Benefits and FeaturesSAT 3C/D/F CONTROLLER VERSES SAT 2C/D CONTROLLER BENEFITSTHE SA

Page 662

WCC III Technical Guide15-315. SAT 3C/D/F INSTALLATIONTypical WCC III System InstallationOE210TYPICALSENSOR(X8)ON/OFF RELAYPUMPS, LIGHTS,ETC.87SATADDR

Page 663 - INSTALLATION GUIDE (SS5003)

WCC III Technical Guide15-415. SAT 3C/D/F INSTALLATIONTypical WCC III InstallationThe SAT 3C controller is used to interface to dedicated Roof Top co

Page 664 - SAT III - SAT II Comparison

WCC III Technical Guide15-515. SAT 3C/D/F INSTALLATIONGlobally Addressable Control PointsGlobally Addressable Control PointsThe main differences betwe

Page 665 - SAT III I/O Terminology

WCC III Technical Guide15-615. SAT 3C/D/F INSTALLATIONSAT 3C Zone Summary Sheet

Page 666 - SAT III I/O Layout Sheet

WCC III Technical Guide15-715. SAT 3C/D/F INSTALLATIONSAT 3D Zone Summary Sheet

Page 667

Table of ContentsINTRODUCTIONWCC III SYSTEM FEATURES ... I-1WCC III - MCD ...

Page 668 - WCCIII System Overview

2. INITIATING THE SYSTEMWCC III Technical Guide2-2WCC III Installation Software - DM1WC011-01XPlease note: Your user name must have suffi cient rights

Page 669

WCC III Technical Guide15-815. SAT 3C/D/F INSTALLATIONSAT 3F Zone Summary Sheet

Page 670 - SAT III Analog Input Wiring

WCC III Technical Guide15-915. SAT 3C/D/F INSTALLATIONDip Switch Settings and LEDs24VAC & GND (POWER CONNECTIONS)This SAT 3C/D/F controller’s powe

Page 671

WCC III Technical Guide15-1015. SAT 3C/D/F INSTALLATIONSAT 3C/D/F Installation and Mounting

Page 672

WCC III Technical Guide15-1115. SAT 3C/D/F INSTALLATIONSAT 3C/D/F Installation and Mounting

Page 673

WCC III Technical Guide15-1215. SAT 3C/D/F INSTALLATIONSAT 3C Satellite Addressing

Page 674

WCC III Technical Guide15-1315. SAT 3C/D/F INSTALLATIONSAT 3D/F Satellite Addressing

Page 675

WCC III Technical Guide15-1415. SAT 3C/D/F INSTALLATIONTUC Addressing

Page 676

WCC III Technical Guide15-1515. SAT 3C/D/F INSTALLATIONRTU-17 Addressing

Page 677

WCC III Technical Guide15-1615. SAT 3C/D/F INSTALLATIONSAT 3F Zone Addressing

Page 678 - SAT III Control Output Wiring

WCC III Technical Guide15-1715. SAT 3C/D/F INSTALLATIONTypical System Configuration with SAT 3C87SATADDRESS2148A3 WIRE ROOM SENSOR WILL NOTREQUIREA LO

Page 679 - SAT III Analog Output Wiring

2. INITIATING THE SYSTEMWCC III Technical Guide2-3Step 6: The mouse cursor will turn to an hourglass-shaped cursor to indicate that the WCC III insta

Page 680

WCC III Technical Guide15-1815. SAT 3C/D/F INSTALLATIONTypical System Configuration with SAT 3D87SATADDRESS2148A3 WIRE ROOM SENSOR WILL NOTREQUIREA L

Page 681

WCC III Technical Guide15-1915. SAT 3C/D/F INSTALLATIONTypical System Configuration with SAT 3F87SATADDRESS2148A3 WIRE ROOM SENSOR WILL NOTREQUIREA LO

Page 682

WCC III Technical Guide15-2015. SAT 3C/D/F INSTALLATIONSystem Components

Page 683

WCC III Technical Guide15-2115. SAT 3C/D/F INSTALLATIONSensors

Page 684

WCC III Technical Guide15-2215. SAT 3C/D/F INSTALLATIONOE320-23, OE324-23, & OE310-21

Page 685

WCC III Technical Guide15-2315. SAT 3C/D/F INSTALLATIONOE330-21 & OE331-21

Page 686 - SAT II CONTROLLER

WCC III Technical Guide15-2415. SAT 3C/D/F INSTALLATIONOE256-01, OE325-01, & PL102224-21

Page 687 - SAT III Binary Input Wiring

16. WCC III V-Out Relay 16. WCC III V-Out Relay Board InstallationBoard InstallationWCC III

Page 688 - Input/Output Terminology

TABLE OF CONTENTS SECTION 16: WCC III V-OUT RELAY BOARD INSTALLATIONOE430-01WCC3 V-Out RELAY board Sequence ...16-1Binary Output Mode of Operati

Page 689

WCC III Technical Guide 16. WCC III V-OUT RELAY BOARD INSTALLATION 16-1OE430-01 InstallationENGINEERINGINSTALLATION GUIDEWCC III V-OUT RELAY BOARD

Page 690

2. INITIATING THE SYSTEMWCC III Technical Guide2-4WCC III Limited Installation Software - DM1WC012-01XPlease note: Your user name must have suffi cien

Page 691 - 15. SAT 3C/D/F

16. WCC III V-OUT RELAY BOARD INSTALLATION WCC III Technical Guide16-287SATADDRESS2148A 3 WIRE ROOM SENSORWILL NOTREQUIRE ALOAD RESISTOR WHEN SETFOR

Page 692 - SECTION 15: SAT 3C/D/F

WCC III Technical Guide 16. WCC III V-OUT RELAY BOARD INSTALLATION 16-3OE430-01 Installation

Page 693 - SAT 3C/D/F Overview

16. WCC III V-OUT RELAY BOARD INSTALLATION WCC III Technical Guide16-4OE430-01 Installation

Page 694 - SAT 3C/D/F CONTROLLER

WCC III Technical Guide 16. WCC III V-OUT RELAY BOARD INSTALLATION 16-5OE430-02 InstallationWCC3 V-Out RELAY board SequenceThere are two modes of

Page 695

16. WCC III V-OUT RELAY BOARD INSTALLATION WCC III Technical Guide16-6OE430-02 Installation87SATADDRESS2148A 3 WIRE ROOM SENSORWILL NOTREQUIRE ALOAD

Page 696 - Typical WCC III Installation

WCC III Technical Guide 16. WCC III V-OUT RELAY BOARD INSTALLATION 16-7OE430-02 Installation

Page 697

16. WCC III V-OUT RELAY BOARD INSTALLATION WCC III Technical Guide16-8OE430-02 Installation

Page 698 - SAT 3C Zone Summary Sheet

17. Binary Input w/Time 17. Binary Input w/Time Delay Board InstallationDelay Board InstallationWCC III

Page 699 - SAT 3D Zone Summary Sheet

TABLE OF CONTENTS SECTION 17: BINARY INPUT W/TIME DELAY BOARD INSTALLATIONWCC3 Binary Input w/Time Delay Board Sequence ...

Page 700 - SAT 3F Zone Summary Sheet

WCC III Technical Guide 17. Binary Input w/Time Delay Board Installation 17-1Installation InstructionsSAT II controller.The eight Binary Inputs on

Page 701 - Dip Switch Settings and LEDs

2. INITIATING THE SYSTEMWCC III Technical Guide2-5Step 6: The mouse cursor will turn to an hourglass-shaped cursor to indicate that the WCC III insta

Page 702

17. Binary Input w/Time Delay Board Installation WCC III Technical Guide17-2SAT III CONTROLLER87SATADDRESS2148A 3WIRE ROOM SENSOR WILL NOTREQUIRE ALO

Page 703

WCC III Technical Guide 17. Binary Input w/Time Delay Board Installation 17-3Installation Instructions87SATADDRESS2148A 3WIRE ROOM SENSOR WILL NOT

Page 704 - SAT 3C Satellite Addressing

17. Binary Input w/Time Delay Board Installation WCC III Technical Guide17-4Installation Instructions

Page 705 - SAT 3D/F Satellite Addressing

18. SAT 3P (Pulsemeter) 18. SAT 3P (Pulsemeter) Controller ManualController ManualWCC III

Page 706 - TUC Addressing

TABLE OF CONTENTSSECTION 18: SAT 3P (PULSEMETER) CONTROLLER MANUALOverview ... 18-1SAT 3P Pulse Inpu

Page 707 - RTU-17 Addressing

18. SAT 3P INSTALLATION GUIDEWCC III Technical Guide18-1Figure 18-1: SAT 3P ControllerSECTION 18: SAT 3P (PULSEMETER) CONTROLLER MANUAL (SS5013)_____

Page 708 - SAT 3F Zone Addressing

WCC III Technical Guide18-218. SAT 3P INSTALLATION GUIDEWhen used in conjunction with the WCC III system, the SAT III controllers and SAT 3P controlle

Page 709

18. SAT 3P INSTALLATION GUIDEWCC III Technical Guide18-3Figure 18-3: SAT 3P Points of InterestPulse Input Terminal Block (LABELED TB1)This 10-positio

Page 710

WCC III Technical Guide18-418. SAT 3P INSTALLATION GUIDEAddress SwitchAn eight position Dip Switch is provided for Satellite addressing. Each SAT 3 ty

Page 711

18. SAT 3P INSTALLATION GUIDEWCC III Technical Guide18-5Basic Wiring InstructionsUse 16 or 18 gauge stranded wire to wire from the KW pulse meter to t

Page 712 - System Components

2. INITIATING THE SYSTEMWCC III Technical Guide2-6WCC III Tenant Override InstallationWCC III Tenant Override Installation Software - DM1WC013-01XPlea

Page 713

WCC III Technical Guide18-618. SAT 3P INSTALLATION GUIDEWhen sharing a common transformer to power other Satellite Controllers, the transformer used f

Page 714

18. SAT 3P INSTALLATION GUIDEWCC III Technical Guide18-7Satellite # _______Specifi es the number of the satellite which you are currently editing. If y

Page 715 - OE330-21 & OE331-21

WCC III Technical Guide18-818. SAT 3P INSTALLATION GUIDEAnalog Input ScreenType:This fi eld is automatically fi lled in by the system. On the SAT 3P, it

Page 716

18. SAT 3P INSTALLATION GUIDEWCC III Technical Guide18-9Alternate Limits Selected By:Specifi es the point that initiates the Alternate mode. When this

Page 717 - Board Installation

WCC III Technical Guide18-1018. SAT 3P INSTALLATION GUIDEThe WCC III system has 50 Energy Consumption Screens. The number directly under the ENERGY CO

Page 718 - INSTALLATION

18. SAT 3P INSTALLATION GUIDEWCC III Technical Guide18-11Energy Consumption ScreenThe units selected will appear for the consumption since last reset

Page 719 - ENGINEERING

WCC III Technical Guide18-1218. SAT 3P INSTALLATION GUIDE

Page 720

19. Power and Switchable19. Power and SwitchableComm BoardComm BoardWCC III

Page 721 - OE430-01 Installation

TABLE OF CONTENTSSECTION 19: POWER AND SWITCHABLE COMM BOARDOverview ... 19-1Power and Switchable RS-4

Page 722

19. POWER AND SWITCHABLE COMM BOARDWCC III Technical Guide19-1Figure 19-1: The Power and Switchable Comm BoardSECTION 19: POWER AND SWITCHABLE COMM B

Page 723

2. INITIATING THE SYSTEMWCC III Technical Guide2-7Step 5: After the installation is complete, the screen shown above will be displayed. Please left-c

Page 724

WCC III Technical Guide19-219. POWER AND SWITCHABLE COMM BOARDPower and Switchable RS-485 Communications BoardFigure 19-2: The Power and Switchable R

Page 725 - OE430-02 Installation

19. POWER AND SWITCHABLE COMM BOARDWCC III Technical Guide19-3WCC III System OverviewOE210TYPICALSENSOR(X8)ON/OFF RELAYPUMPS, LIGHTS,ETC.87SATADDRESS2

Page 726

WCC III Technical Guide19-419. POWER AND SWITCHABLE COMM BOARDDiagram of WCC III SystemThe heart of the WCC III system consists of an Internet Applian

Page 727 - Delay Board Installation

19. POWER AND SWITCHABLE COMM BOARDWCC III Technical Guide19-5WCC III - MCD Typical System ArchitectureFigure 19-5: WCC III typical system architectu

Page 728 - BOARD INSTALLATION

WCC III Technical Guide19-619. POWER AND SWITCHABLE COMM BOARDFigure 19-6: Typical WCC III System Communications Wiring - Not the recommended and pre

Page 729 - Installation Instructions

19. POWER AND SWITCHABLE COMM BOARDWCC III Technical Guide19-7Figure 19-7: Typical WCC III System Communications Wiring - The recommended and preferr

Page 730

WCC III Technical Guide19-819. POWER AND SWITCHABLE COMM BOARD

Page 731

20. WCC II TO WCC III20. WCC II TO WCC IIIGLOBAL BRIDGE MANUALGLOBAL BRIDGE MANUALWCC III

Page 732

TABLE OF CONTENTSSECTION 20: WCC II to WCC III GLOBAL BRIDGE MANUALOverview ... 20-1WccUtility.EXE Pr

Page 733 - Controller Manual

WCC III Technical Guide20-120. GLOBAL BRIDGE BOARD INSTALLATIONSECTION 20: WCC II to WCC III GLOBAL BRIDGE MANUAL (SS5012)___________________________

Page 734 - CONTROLLER MANUAL

2. INITIATING THE SYSTEMWCC III Technical Guide2-8How to Start or Run the WCC3.exe Program (SS5021)The WCC3.exe shortcut icon should have been install

Page 735

WCC III Technical Guide20-220. GLOBAL BRIDGE BOARD INSTALLATIONWccUtility.EXE Program Setup Considerations and Limitations for Global BridgeTo setup t

Page 736 - 18. SAT 3P INSTALLATION GUIDE

WCC III Technical Guide20-320. GLOBAL BRIDGE BOARD INSTALLATIONSET GLOBAL MAP VIEWFrom the WCCUtility.EXE program there are two choices for the “WCC I

Page 737 - SAT 3P Components

WCC III Technical Guide20-420. GLOBAL BRIDGE BOARD INSTALLATIONFigure 20-3: The Set Bridge Map Window SET BRIDGE MAPFrom the WccUtility.exe program t

Page 738 - SAT 3P Addressing

WCC III Technical Guide20-520. GLOBAL BRIDGE BOARD INSTALLATIONTroubleshooting the WCC III RS-485 Communications LoopWhat is the WCC III RS-485 commun

Page 739

WCC III Technical Guide20-620. GLOBAL BRIDGE BOARD INSTALLATION2nd Condition: The WCC III RS-485 communications loop is not plugged into a SAT III con

Page 740

WCC III Technical Guide20-720. GLOBAL BRIDGE BOARD INSTALLATIONStep 3: SAT II controller Manchester boards’ impedance mismatching problem:a. When in

Page 741

WCC III Technical Guide20-820. GLOBAL BRIDGE BOARD INSTALLATIONWCC II Manchester Communication BoardsWattMaster Controls, Inc. in the past has produce

Page 742

WCC III Technical Guide20-920. GLOBAL BRIDGE BOARD INSTALLATIONPlease note the following:• The later Manchester Communication Board will need to have

Page 743

WCC III Technical Guide20-1020. GLOBAL BRIDGE BOARD INSTALLATION

Page 744

VAV/Zone ControllerTechnical Guidewww.wcc-controls.com

Page 745

2. INITIATING THE SYSTEMWCC III Technical Guide2-9The Remote Access Dialog Box will allow you to enter multiple WCC III – MCD IP addresses based upon

Page 746

Table of ContentsWattMaster Controls Inc.8500 NW River Park Drive · Parkville , MO 64152Toll Free Phone: 866-918-1100PH: (816) 505-1100 · FAX: (816)

Page 747 - Comm Board

3VAV/Zone Controller Technical GuideOperator InterfaceFeaturesVAV/Zone ControllerThis manual applies to the VAV/Zone Controller that is included in

Page 748 - SWITCHABLE COMM BOARD

VAV/Zone Controller Technical GuideOperator Interface4Figure 3: VAV/Zone Controller Component LocationsController OverviewFigure 2: OE322 Output Exp

Page 749

Operator Interface VAV/Zone Controller Technical Guide 5The following inputs and outputs are available on the VAV/Zone Con-troller and the OE322 Out

Page 750

VAV/Zone Controller Technical GuideOperator Interface63 Stage Heating ApplicationsIf three stages of electric heat are confi gured, relays #2 and #3 wi

Page 751 - WCC III System Overview

Operator Interface VAV/Zone Controller Technical Guide 7Figure 4: VAV/Zone Controller WiringController Installation & WiringCorrect wiring of t

Page 752 - WCC III System Features

VAV/Zone Controller Technical GuideOperator Interface8 Controller Inputs and OutputsVAV/Zone Controller - Transformer SizingWhen sizing transformers f

Page 753

Operator Interface VAV/Zone Controller Technical Guide 9Figure 5: VAV/Zone Controller Transformer Sizing Controller Inputs and Outputs

Page 754

VAV/Zone Controller Technical GuideOperator Interface10Slaved Zone Damper WiringFor large zones it may be necessary to have more than one air damper c

Page 755

Operator Interface VAV/Zone Controller Technical Guide 11Expansion Board Installation & WiringWiring ConsiderationsExpansion Boards are used to

Page 756

2. INITIATING THE SYSTEMWCC III Technical Guide2-10Left-click <Cancel> to return to the Connection Dialog Box that was fi rst displayed. The

Page 757 - 20. WCC II TO WCC III

VAV/Zone Controller Technical GuideOperator Interface12Figure 8: Expansion Board Wiring For Electric Heat ApplicationsWattMaster Part #OE322Relay Exp

Page 758

Operator Interface VAV/Zone Controller Technical Guide 13Expansion Board Installation & WiringFigure 9: Expansion Board Wiring For Modulating H

Page 759

VAV/Zone Controller Technical GuideOperator Interface14In order to have a trouble free start-up it is important to follow a few simple procedures. Bef

Page 760 - Setup Global Bridge

Operator Interface VAV/Zone Controller Technical Guide 15Start-Up & CommissioningPower Wiring One of the most important checks to make before po

Page 761 - Setup Global Map View Screen

VAV/Zone Controller Technical GuideOperator Interface16 Start-Up & CommissioningInitializationUpon applying power to the VAV/Zone Controller the f

Page 762 - Set Bridge Map

Operator Interface VAV/Zone Controller Technical Guide 17VAV/Zone Confi guration & SetupThere are a few confi guration selections available to the

Page 763 - Communications Loop

VAV/Zone Controller Technical GuideOperator Interface18 Sequence of OperationsDuring Override operations, the user can cancel the override by press-in

Page 764 - Troubleshooting the WCC II

Operator Interface VAV/Zone Controller Technical Guide 19Damper PositionsThe actual values for the minimum damper positions that are described in t

Page 765

VAV/Zone Controller Technical GuideOperator Interface20 Sequence of OperationsSeries Flow Fan TerminalsIf the VAV/Zone Controller has been confi gured

Page 766 - WCC II Manchester Boards

Operator Interface VAV/Zone Controller Technical Guide 21Box Fan Relay & Reheat Relay Staging Occupied ModeRelays Stage On AtSeries FanParallel

Page 767

2. INITIATING THE SYSTEMWCC III Technical Guide2-11Assigning Operator Access Codes Access codes can be assigned for up to 16 operators with 4 levels

Page 768

VAV/Zone Controller Technical GuideOperator Interface22 Sequence of OperationsSeries Flow Fan TerminalsIf the VAV/Zone Controller has been confi gured

Page 769 - Technical Guide

Operator Interface VAV/Zone Controller Technical Guide 23Sequence of OperationsIn all cases, before the series box fan can be activated, the air dam

Page 770

VAV/Zone Controller Technical GuideOperator Interface24Sequence of OperationsFigure 12: VAV Box Controller Status ScreenFigure 13: VAV Box Controlle

Page 771

Operator Interface VAV/Zone Controller Technical Guide 25 Sequence of OperationsFigure 14: VAV Box Controller Global Binaries, Global Analogs, and

Page 772

VAV/Zone Controller Technical GuideOperator Interface26Of course, different space temperature errors and different Integral values cause this calculat

Page 773 - Controller Inputs and Outputs

Operator Interface VAV/Zone Controller Technical Guide 27Internal Trend LoggingThe Satellite Controller can maintain an Internal Trend Log which rec

Page 774

VAV/Zone Controller Technical GuideOperator Interface28TroubleshootingUsing LEDs To Verify OperationThe VAV/Zone controller is equipped with LEDs that

Page 775

Operator Interface VAV/Zone Controller Technical Guide 29Other ChecksSpace Temperature SensorIf the Space Temperature Sensor is not reading a valid

Page 776 - Operator Interface

VAV/Zone Controller Technical GuideOperator Interface30TroubleshootingTUC2R Communications Troubleshooting with a Digital VoltmeterThe voltage measure

Page 777

Operator Interface VAV/Zone Controller Technical Guide 31 TroubleshootingFigure 19: Typical TUC2R RS485 TUC Communications DC Voltage Measurements

Page 778 - OE523, OE738, OE282-03

Table of ContentsSECTION 1: GENERAL INSTRUCTIONS, continuedDATA REGISTERS ... 1-9Time Clock ...

Page 779 - Wiring Considerations

2. INITIATING THE SYSTEMWCC III Technical Guide2-12 "UP"Button"DOWN" Button "SELECT" "HOLD""ROTATE"

Page 780

VAV/Zone Controller Technical GuideOperator Interface32TroubleshootingThermistor Sensor Testing Instructions1.) Use the resistance column to check the

Page 781

Operator Interface VAV/Zone Controller Technical Guide 33AppendixVAVZ II ControllerWattMaster Controls, Inc. has a new VAV Zone Controller available

Page 782 - Start-Up & Commissioning

VAV/Zone Controller Technical GuideOperator Interface34AppendixFigure 22: OE217-01 Digital Sensor

Page 783

Operator Interface VAV/Zone Controller Technical Guide 35Notes

Page 784 - Start-Up & Commissioning

Form: WCCIII-VAVZ-TGD-01C Printed in the USA September 2010 All rights reserved Copyright 2010 WattMas

Page 785 - Sequence of Operations

VAV/Zone ControllerActuator PackageTechnical Guidewww.wcc-controls.com

Page 786 - Sequence of Operations

Table of ContentsWattMaster Controls, Inc.8500 NW River Park Drive, Parkville, MO 64152Toll Free Phone: 866-918-1100PH: (816) 505-1100 · FAX: (816)

Page 787 - Unoccupied Mode

Features VAV/Zone Controller Actuator PackageThis manual applies to the VAV/Zone Controller Packages that are included in the following Orion product

Page 788 - Parallel Flow Fan Terminals

Figure 1: OE742-32-VAVF Pressure Dependent VAV/Zone Controller Actuator Package DimensionsP.D. VAV/Zone Controller Actuator Package Dimensions4

Page 789

P.I. VAV/Zone Controller Actuator Package DimensionsFigure 2: OE744-32-VAVF Pressure Independent VAV/Zone Controller Actuator Package Dimensions5VA

Page 790

2. INITIATING THE SYSTEMWCC III Technical Guide2-13SELECTDESELECTCHECKHEART BEATUP/DOWN ITEM SELECTSUBMENU UP SELECTSUBMENU DOWN SELECTThe LCD Charact

Page 791

Figure 3: OE742-32 Pressure Dependent VAV/Zone Controller Actuator Package Component LocationsVAV/Zone Controller Actuator Package Component Locati

Page 792

Figure 5: OE325-01 Zone Controller Expansion Module DimensionsFigure 6: OE325-01 Zone Controller Expansion Module Component LocationsZone Contro

Page 793

The following inputs and outputs are available on the VAV/Zone Controller and the OE325-01 Zone Controller Expansion Module. For component locations

Page 794

Controller Installation & WiringGeneralCorrect wiring of the VAV/Zone Controller is the most important factor in the overall success of the cont

Page 795

Zone Controller Actuator Package Wiring10OE28224 VAC Transformer. Size AsRequired For Number Of ControllersConnected. Each VAV/Zone ControllerActuat

Page 796 - Troubleshooting

Zone Controller Expansion Module WiringFigure 8: Zone Controller Expansion Module Wiring - Fan Terminals And/Or Staged Electric Heat11VAV/Zone

Page 797 - Troubleshooting

Zone Controller Expansion Module WiringFigure 10: Zone Controller Expansion Module Wiring - Fan Terminals And/Or 2 Position HW HeatFigure 9: Zon

Page 798

Zone Controller Expansion Module WiringFigure 11: Zone Controller Expansion Module Wiring - Fan Terminals And/Or SCR Electric Heat13VAV/Zone Con

Page 799

Power/Comm Board WiringFigure 12: Communication & Power Wiring Diagram10OE282TB3STATGND24VACRSHLDTTB2RECTSHLDR24 VACGNDwww.orioncontrols.comWa

Page 800

Transformer SizingFigure 13: VAV/Zone Controller Actuator Package Transformer Sizing15VAV/Zone Controller Actuator Package Technical Guide

Page 801 - Appendix

2. INITIATING THE SYSTEMWCC III Technical Guide2-14CrystalfontzRx: 0.0 Down lTx: 0.0 UP 0IP PacketAn IP packet is the formatted unit of data tha

Page 802

Slaved Zone Damper WiringFor large zones, it may be necessary to have more than one air damper controlled by a VAV/Zone Controller Actuator Package an

Page 803

Addressing & Powering UpFigure 15: Address Switch SettingGeneralIn order to have a trouble free start-up, it is important to follow a few simp

Page 804

Table 2: SAT 3D Addressing to TUC Control PointsSAT 3D ADDRESSING TO TUC CONTROL POINTSSAT 3DAddressVAVZIIAddressSAT 3D Analog INSpace TempData Regis

Page 805 - Actuator Package

Start-Up & CommissioningTable 3: SAT 3F Addressing to TUC Control PointsSAT 3F ADDRESSING TO TUC CONTROL POINTSSAT 3FAddressVAVZ IIAddressSAT 3F

Page 806

Initialization and Programming Power Wiring One of the most important checks to make before powering up the sys-tem for the fi rst time is to confi rm p

Page 807 - Features

VAV/Zone Confi guration & SetupThere are a few confi guration selections available which can be used to tailor the software operation to match t

Page 808

Scheduling Occupied/Unoccupied Mode The VAV/Zone Controller monitors the communications loop for its Oc-cupied and Unoccupied mode of operation comm

Page 809

Damper Positions and Occupied Mode SequencesSpace Heating Mode This mode occurs when the Space Temperature falls below the Space Heating Setpoint. Off

Page 810

Space Heating ModeOccupied Space Heating mode is initiated by the temperature in the space falling below the Occupied Heating Setpoint. If the HVAC u

Page 811

Unoccupied Mode Sequences Parallel Flow Fan TerminalsOn parallel fan powered terminal units, the fan will run whenever Space Heating mode is active

Page 812 - Inputs and Outputs

2. INITIATING THE SYSTEMWCC III Technical Guide2-15 Crystalfontz OPTIONSHeartbeatOptions Menu – Heart Beat Selection Press either

Page 813

Space Heating ModeDuring unoccupied mode, the HVAC unit is normally off. Unoccupied Space Heating mode is initiated by the temperature in the space f

Page 814 - Installation & Wiring

Damper Control and Tenant Override Logs Damper ControlThe damper position is calculated by the mode and demand from the space sensor. Included in this

Page 815

Internal Trend Logging Internal Trend LoggingThe Satellite Controller can maintain an Internal Trend Log, which records a fi xed set of values at an

Page 816

Force Modes Force Modes or OverridesThe VAV/Zone Controller damper can be forced to one of several po-sitions. These force modes aid the user during

Page 817

Analog Input ScreensProgramming a SAT 3F Satellite so that Control Points can be used in Global Calculations or for Trend LoggingThe SAT 3F controller

Page 818 - Power/Comm Board Wiring

Analog Input ScreensFigure 17: Analog Input ScreenDescription:On the Analog Input Screen you may want to fi ll in the description fi eld with a short

Page 819 - Transformer Sizing

Control Output ScreensFigure 18: Control Output Summary ScreenOn a SAT 3F, and only on the SAT 3F, the Control Output Screen needs to be programmed f

Page 820 - Slaved Zone Damper Wiring

Control Output ScreensFigure 19: Control Output ScreenMode:This is a choice fi eld for the mode type. A list of available choices will be displayed at

Page 821 - Controller Addressing

Logic Switch Summary ScreenFigure 20: Logic Switch Summary ScreenThe Logic Switch Screen must also be fi lled out in order for the Binary points to b

Page 822

LED TroubleshootingUsing LEDs To Verify OperationThe VAV/Zone Controller is equipped with LEDs that can be used as very powerful troubleshooting too

Page 823

2. INITIATING THE SYSTEMWCC III Technical Guide2-16 Crystalfontz ContrastOn BrightnessOptions Menu – CfontzPacket Submenu – On Brightness

Page 824

Other Checks Space Temperature SensorIf the Space Temperature Sensor is not reading a valid temperature, fi rst make sure that the modular cable connec

Page 825 - VAV/Zone Confi guration

Temperature Sensor Testing Temperature Sensor TestingThe following sensor voltage and resistance table is provided to aid in checking sensors that a

Page 826

Modular and Digital Room Sensor TestingFigure 22: Testing Resistance & Voltage On Modular & Digital Room Sensors38 VAV/Z

Page 827 - Occupied Mode Sequences

Notes39VAV/Zone Controller Actuator Package Technical Guide Troubleshooting

Page 828

Form: WCC3-ZCAP-TGD-01A Printed in the USA September 2010All rights reserved

Page 830 - Unoccupied Mode Sequences

Form: WCC3MASTER-ALL-01B Printed in the USA October 2013 All rights reserved. Copyright 2013 WattMas

Page 831 - Tenant Override Logs

2. INITIATING THE SYSTEMWCC III Technical Guide2-17The WCC III - MCD The WCC III – MCD OverviewThe WCC III – MCD was converted from the Windows XP ope

Page 832 - Internal Trend Logging

2. INITIATING THE SYSTEMWCC III Technical Guide2-18Using the MCD-Menu ProgramUsing the MCD-Menu ProgramOverviewThe default administration username is

Page 833 - Force Modes

2. INITIATING THE SYSTEMWCC III Technical Guide2-19Using the MCD-Menu ProgramStep 3: Pressing the “enter” key or the “d” key will result in the next

Page 834 - Programming a SAT 3F

2. INITIATING THE SYSTEMWCC III Technical Guide2-20Using the MCD-Menu ProgramAfter you have entered in all of the required IP addresses, subnet masks,

Page 835 - Analog Input Screens

2. INITIATING THE SYSTEMWCC III Technical Guide2-21Using the MCD-Menu ProgramCopying fi le: /home/wcciii/.wine/drive_c/Backtask/ProportionalReset.datCo

Page 836

Table of ContentsANALOG OUTPUT SUMMARY SCREEN... 3-63WCC III SYSTEM LOGGING ... 3-68SAT Trend Log Summary Screen

Page 837

2. INITIATING THE SYSTEMWCC III Technical Guide2-22Using the MCD-Menu ProgramCopying fi le: /home/wcciii/.wine/dosdevices/d:/TenantOverrideRecord.datCo

Page 838

2. INITIATING THE SYSTEMWCC III Technical Guide2-23Using the MCD-Menu ProgramRestart LCD Driver (Choice #6)On the front of the WCC III – MCD, there is

Page 839 - LED Troubleshooting

2. INITIATING THE SYSTEMWCC III Technical Guide2-24Using the MCD-Menu ProgramShutdown MCD (Choice 10)There are times that occur when you would need to

Page 840 - Diagnostics

2. INITIATING THE SYSTEMWCC III Technical Guide2-25Webmin Administration - Limited VersionHow to Access the Linux-Based Limited Functions of the Opera

Page 841 - Temperature Sensor Testing

2. INITIATING THE SYSTEMWCC III Technical Guide2-26Step 3: If your login is successful, the webmin main page will display as shown above. Various im

Page 842

2. INITIATING THE SYSTEMWCC III Technical Guide2-27Webmin Administration - Limited VersionOn the Left hand side of the Main webmin page is a very limi

Page 843

2. INITIATING THE SYSTEMWCC III Technical Guide2-28Webmin Administration - Limited VersionMCD CONTROLS Custom Commands ModulesTo ease the management o

Page 844

2. INITIATING THE SYSTEMWCC III Technical Guide2-29System and Server Module ScreenThis screen sets up a software “watchdog” function on the “Backtask”

Page 845

2. INITIATING THE SYSTEMWCC III Technical Guide2-30The Filesystem Backup Module This module allows you to create and edit the scripts that are run at

Page 846

2. INITIATING THE SYSTEMWCC III Technical Guide2-31Webmin Administration - Limited VersionRunning a Backup Once a backup job has been defi ned, it can

Comments to this Manuals

No comments